18.2 EDS 3000 WITH THIN FILM DMS SENSOR CELL;
RELATIVE PRESSURE STARTING AT 40 BAR (1000 PSI)
Input data
Measuring
ranges
bar 40 100 250 400 600
Overload
ranges
bar 80 200 500 800 1000
Burst
pressures
bar 200 500 1000 2000 2000
Measuring ranges
psi
1000
3000 6000 9000
Overload
ranges
psi 2900 7250 11600 11600
Burst
pressures
psi 7250 14500 29000 29000
Mechanical connection
As per model code
Torque value
20 Nm [15 ft-lb ]
Parts in contact with fluid
Mechanical connection: Stainless steel
Sensor cell: Stainless steel
Seal: FPM
Output data
Output signals
Output 1: switching output
Output 2: can be configured as switching output or
as analogue output
Switch outputs
PNP transistor switching outputs
Schaltstrom: SP1: max. 0.1 A / SP2: max. 0.25 A
Schaltzyklen. > 100 million
Analogue output, permitted load resistance
selectable:
4 .. 20 mA
load resistance max. 500
Ω
0 .. 10 V
load resistance min. 1 k
Ω
Accuracy to DIN 16086,
Max. setting
≤
± 0.5 % FS typ.
≤
± 1 % FS max.
Temperature drift
Typ.
zero
point
Max.
≤
± 0.015 % FS / °C [
≤
± 0.0085% FS/°F]
≤
± 0.025 % FS / °C [
≤
± 0.014 % FS/°F]
Temperature drift
Typ.
range
Max.
≤
± 0.015 % FS / °C [
≤
± 0.0085% FS/°F]
≤
± 0.025 % FS / °C [
≤
± 0.014 % FS/°F]
Repeatability
≤
± 0.25 % FS max.
Reaction time
< 10 ms
Long term drift
≤
± 0.3 % FS typ. / year
Environmental conditions
Compensated temperature range
-10 .. +70 °C [-14 .. +158º F]
Operating temperature range
-25 .. +80 °C [-13 .. +176º F]
Storage temperature range
-40 .. +80 °C [-40 .. +176º F]
Fluid temperature range
-25 .. +80 °C [-13 .. +176º F ]
mark
EN 61000-6-1 / 2 / 3 / 4
Vibration resistance according to
DIN EN 60068-2-6 (0 .. 500 Hz)
≤
10 g
Shock resistance according to
DIN EN 60068-2-27 (11 ms)
≤
50 g
Protection class to IEC 60529
IP 67
Other data
Supply voltage
9 .. 35 V DC
without analogue output
18 .. 35 V DC
with analogue output
Residual ripple of supply voltage
≤
5 %
Current consumption
≤
0.535 A
with active switch outputs
≤
35 mA
with inactive switch outputs
≤
55 mA
with inactive switching output
and
analogue
output
Display
4-digit, LED, 7 segment, red, height of digits 7 mm
Weight approx.
120
g
Note: Excess voltage, override protection an shortcircuit protection are provided.
FS (Full Scale) = relative to the full measuring range