5.4.1 Commissioning with a directly connected end
device
In the case of several DHCP servers, there are connectivity
problems in the network. The setting up of the DATA+ BOX is
then not possible.
Disconnect other DHCP servers from the network.
ü
The DATA+ BOX is directly connected to the ETH 1 con-
nection on an Ethernet interface of the end device.
ü
At the Ethernet interface of the end device, the assign-
ment for IPV4 addresses -via DHCP is set. Disconnect
other DHCP severs from the network.
1.
By means of a suitable network cable, connect the
ETH 1 connection of the DATA+ BOX to a network con-
nection of your end device.
2.
Connect a suitable power supply unit to the POWER
connection of the DATA+ BOX and switch it on.
ð
The POWER LED of the DATA+ BOX lights up in
green.
3.
Open an HTML5enabled browser.
We recommend Google Chrome or Mozilla Firefox.
Keep your browser updated to the latest version.
4.
In the address bar, enter:
Enter exactly in this format, then https://.
5.
Your browser may show a warning message that the
connection is insecure.
This is due to a missing valid certificate and you can ig-
nore it. To do this, depending on your browser, you must
either add an exception or confirm that you still want to
be redirected.
Example message from Firefox: Press
Advanced... here,
then
Accept Risk and continue.