OLF 5 with Temperature sensor
HYDAC Filtertechnik GmbH
en
Page 10
BeWa OLF-5 LL-ET_3321664a en.doc
2006-10-06
3 Description
The OLF-5 series is based on the DIMICRON
®
off-line filtration concept.
Using the OLF-5 results in fewer oil changes, extension of the system filter life and service
life of components, and higher availability of machinery and equipment.
The unit can be equipped with filter elements with a filtration rating of up to 2 µm absolute,
with a contamination retention capacity of up to 200 g acc. to ISOMTD.
3.1 OLF
5/4-x
The OLF-5/4 filter unit range was especially designed for hydraulic lubrication systems (gear
boxes) with reservoir volumes of up to ca. 300 liters (85 US gal.). The filter units work with a
flow rate of 4 l/min. (1.01 US gal/min).
3.2 OLF-5/15-x
The OLF-5/15 range was especially designed for hydraulic systems with reservoir volumes of
up to ca. 2,000 gal. The filters work with a flow rate of between 5 and 15 l/min.
3.3
Restrictions Pertaining to the Use of the OLF 5
We recommend operating the filter unit with mineral oils or mineral oil-
based media in accordance with DIN 51524, 51525. Do not use other
operating fluids without our consent.
Contact us before using other fluids.