FMMP
Performing maintenance
Performing maintenance
Replace the filter element at least every six months.
HYDAC Filter Systems GmbH
en
Page 20 / 28
BeWa FMMP 3360764 en 2009-06-05.doc
2009-06-05
Changing th
lement
e Filter E
WARNING
Hydraulic systems are under pressure
Bodily injury
►
The hydraulic system m
e d
before performing any w
system.
ust b
epressurized
ork on the hydraulic
Item
Designation
10
O-ring
10.77x 2.62
20
Filter element
25 µm
30
O-ring
20x 2
40
Support ring
Ø 20
50
Endplate