FMMP
Technical specifications
FMMP components
2
1
4
5
2
3
HYDAC Filter Systems GmbH
en
Page 14 / 28
BeWa FMMP 3360764 en 2009-06-05.doc
2009-06-05
Item
Designation
1
FMMP manifold block
2
Test point 1604 (IN/OUT)
3
Filter element insert
4
ContaminationSensor CS1000 series
5
Socket plug, 8-pole, M12x1, with screw clamp
Restrictions pertaining to use
NOTICE
Impermissible operating fluid
The unit will be damaged
►
The unit may only be used with mineral oils (or raffinates whose basis is
mineral oil).