FluidMonitoring Module – FMM-O-M
Attaching the FMMP mechanically
Attaching the FMMP mechanically
We recommend installing the unit vertically, so that the flow direction is from bottom
to top. When selecting the installation site, check the ambient conditions such as
temperature, dust, water, etc. The CS features a protection rating of IP 67 according
to DIN 40050 / EN60529 / IEC 529 / VDE 0470
The FMM can be mounted as follows:
Ⓐ
the two mounting holes in the installation block using 2x cylindrical screws
M6 x 55 mm according to ISO 4762
Ⓑ
the two mounting holes in the CS 1000 using 2x cylindrical screws
M8 x 50 mm according to ISO 4762
Ⓒ
the four threaded holes in the installation block using 4x M6 screws
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 18 / 28
MoWa FMM-O-M 3492448a en-us 2010-12-15.doc
2010-12-15
9
0
50
35
90
A
C
B
83