10. Insert the new filter elements into the element
mount by rotating them slightly while applying
pressure to the element
Do not use excessive force or a hammer,
etc.
11. Place the element retaining plate
[B]
back in
place making sure it is pointed in the right
direction so that it secures all the filter elements
in place.
Insert the cotter pins
[A]
in the designated
holes.
The cotter pins can be more easily
inserted if you lift up the knob
[C]
.
[A]
[B]
12. Clean the sealing surface on the housing.
Check the O-ring for damage. Replace it if
necessary.
Wet the O-ring with fluid and insert it.
13. Clean the sealing surface on the cover.
Put the cover on.