3.8.1 Function
This chapter provides detailed information on how the filter unit
functions.
Fig. 13:
Operating principle of the filter unit
The filter unit has a motor-pump assembly
(310)
for which the
vane pump is integrated directly in the connector head
(110)
.
The drive motor
(310)
is, depending on the version, either an
electric motor with direct current or alternating current or an air
motor.
The connection voltage/pressure specification can be found on
the name plate of the drive motor
(310)
or through the model
code of the filter unit, see
The units with an electrical motor have an on/off switch
(330)
on the terminal box
(330)
for the electric motor
(310)
and a
connector cable with power plug
(331)
. The Type
MFU-...S
units have a motor protection switch in the terminal box to pro-
tect them against electrical overload.