Adjusting the feet 0°⇨ 44°
To adjust both feet from 0° to 44°, proceed as follows:
1.
Fully unscrew both screws counterclockwise with an
Allen key.
2.
Rotate the foot ≈ 22° outwards so that the bores in the
foot can be seen in the other threaded hole at the 22°
position in the filter head.
3.
Rotate the two screws clockwise into the other threaded
holes (position 22°) and tighten them securely with a
3 Nm torque.
NOTICE! Ensure that the screws are located fully in-
side the threaded holes. If the screws protrude out of
the threaded hole, the position has not been chosen
correctly. Select the right position using the hole in
the foot.
O
The adjustment of the feet from 0° to 44° is completed.