Starting up the unit
FAM 5
en(us)
44 / 100
BEWA FAM5 3667663b en-us 2012-12-12.doc
2012-12-12
Starting up the unit
NOTICE
Connection IN / OUT closed
The unit will be destroyed
►
Check to be sure that all of the locking fixtures at the inlet / outlet are
in "open" position each time before start-up.
Starting unit
To switch on the unit, proceed as follows:
1.
Switch on the unit at the main switch
and wait until the signal
lamp "Fault / Unit off" lights up.
2.
Start up the unit by pressing the on switch
.
3.
Depending on the filling level in the vacuum column, the motor pump
assembly (4.0) starts to suck either from the vacuum column or the
tank via the suction strainer (4.02) and the 3/2 directional valve
(3.85).
The flow rate is split up in the flow divider (4.54). One part is funneled
to the vacuum column (3.0), the other back to the tank via the fluid
filter (6.0).
The vacuum pump (7.0) builds up the negative pressure in the
vacuum column (3.0) required for dewatering and degassing.
4.
Set the required underpressure using the vacuum gauge (3.68). See
page 45 for details.
5.
Vent the filter housing. See page 47 for details.