Hydraulic Connection of the CSM
CSM 1000 Series
en
26 / 48
MoWa CSM1000 3512624c en-us 2012-11-26.doc
2012-11-23
Magnetic coupling (only CSM 1xxx-4…)
The CSM1xx0-4… is equipped with a magnetic coupling between the electric motor
and the pump.
NOTE
Slipping magnetic coupling
Fluid is no longer being pumped, the magnetic coupling starts to make noises
and is destroyed.
►
A) Switch the unit off.
►
B) Check the pump temperature. Switch the unit on only after the pump has
cooled down to below 50°C.
►
C) Check if the return line (OUT) is open.
►
D) Check the pressure setting on the pressure gauge. Correct the pressure
setting if necessary.