Hydraulic Connection of the CSM
Suction port connection - IN
NOTE
Overpressure at the suction port connection (IN)
The unit will be destroyed
►
Note the maximum pressure on the suction port connection IN
for CSM1xxx-1 = -0.4 bar - 0.5 bar
for CSM1xxx-2 = -0.4 bar - 120 bar
for CSM1xxx-4 = -0.4 bar - 80 bar
Make the suction-side connection with a flexible hose that is resistant to negative
pressure or with pipelines. The nominal size of the connecting lines must be at least
as large as the cross-section of the unit in order to prevent excessively high
pressure loss.
Suction connection to the tank must be done in a manner so that it is always below
the oil level.
NOTE
Severe contamination
The unit will be damaged
►
Do not prime directly at the bottom of the tank
►
Do not prime in the sump
►
Never prime without a built-in suction screen
The greatest contamination is found on the bottom of the tank. All
impurities and other particles are deposited on the bottom of the tank.
Make the suction-side connection with a flexible hose that is resistant to negative
pressure or with pipelines. The nominal size of the connecting lines must be at least
as large as the cross-section of the unit in order to prevent excessively high
pressure loss.
Suction connection to the tank must be done in a manner so that it is always below
the oil level.