Errors and troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 32 / 36
BeWa CMP1321 3765034 en 2012-09-25.doc
2012-09-25
Errors and troubleshooting
error
Cause(s)
Remedy
The pump is conveying in the
wrong direction.
Check the direction of
rotation of the motor, if
necessary change the
phases in the supply line.
Shut-off device outside of the
CMP in the suction or
pressure line is closed.
Open the shut-off device.
Suction strainer is clogged.
Clean the suction strainer.
No flow
The coupling between the
motor and the pump is loose
or faulty.
Check the coupling for
proper functioning.
No function
Not connected to power
supply.
Check the electrical
connection, the plug,
cables and socket on the
CMP
For CS1000 error messages, refer to the corresponding chapter in your CS1000
operating and maintenance manual.