EDS 4000 Explosion Proof / Flame Proof
Page 8 of 30
Status: 08/01/14
HYDAC ELECTRONIC GMBH
Mat. No.: 669837
7. Model code to identify the delivered part
EDS 4 4 X X – XXXX – X X – D X – 000 (psi) (XX)
Mechanical Connection
2 = G1/2 DIN 3852 (male)
4 = G1/4 A DIN 3852 (male)
6 = 7/16-20 UNF 2A (SAE4, male)
5 = 7/16-20 UNF 2B (SAE4, female)
7 = 9/16-18 UNF 2A (SAE6, male)
8 = 1/4-18 NPT (male)
C = SF250CX20, Autoclave
(7/16-20 UNF 2B, female)
F = 1/4 -18 NPT (female)
W = 1/2 -14 NPT (male)
Electrical Connection
9 = Conduit connection 1/2-14 NPT
- single leads
G = Conduit connection 1/2-14 NPT
- open ended cable
Measuring Ranges
Measuring ranges are shown in bar or psi
(in case of psi see additional declaration)
- 5 digits if more than 9999 psi -
Number of switching outputs
1 = 1 switching output
2 = 2 switching outputs
Output technology
F = Factory-set
P = Programmable
Approval
D = CSA
Explosion Proof - seal not required
ATEX Flame Proof
IECEx Flame Proof
Gauge type
S = Sealed Gauge
≥
40 bar [
≥
500 psi]
V = Vented Gauge < 40 bar [< 500 psi]
Modification Number
000 = Standard
On units with a different modification number, please read the label or the
technical amendment details supplied with the unit.
(psi)
Additional declaration for psi version (escaped for bar version)
Cable length
Shown in m or inch