6. Technical Data
Input data
Measuring ranges
bar
6
16
40
60
100
250
400
600 1000
Overload ranges
bar
15
32
80
120
200
500
800 1000 1600
Burst pressures
bar
100
200
200
300
500 1000 2000 2000 3000
Measuring ranges
psi
100
200
300
500 1000 1500 3000 5000 6000 9000 10000
290
460 1160 1160 2900 2900 7250 11600 11600 14500 14500
1450 2900 2900 2900 7250 7250 14500 29000 29000 29000 29000
Overload ranges
psi
Burst pressures
psi
Mechanical connection
see model code / dimensions
Torque rating
see dimensions
Parts in contact with medium
1.4542 (630); 1.4571 (316); 1.4435 (316L); 1.4404 (316L); 1.4301 (304)
Seal: FPM
Conduit / housing material
1.4404; 1.4435 (316L)
Output data
Accuracy to DIN 16086,
Max. setting
Typ.
Max.
≤
±
0.5 % FS
≤
±
1.0 % FS
Repeatability
Max.
≤
±
0.1 % FS
Temperature drift
Max.
Max.
≤
±
0.017% FS / °F [0.03 % FS / °C] Zero Point
≤
±
0.017% FS / °F [0.03 % FS / °C] Over range
Switching output
1)
1 or 2 PNP switching outputs
Output load
max 1.2 A with 1 switching output
max 1 A each with 2 switching outputs
Switching points
2)
user-programmable with HPG 3000 or factory-set
Switch-back points
2)
user-programmable with HPG 3000 or factory-set
NO or NC function
2)
user-programmable with HPG 3000 or factory-set
Switch delay time
8 .. 2000 ms
user-programmable with HYDAC programming unit HPG 3000
Long term drift
Typ.
≤
±
0.3 % FS / year
Ambient conditions
Compensated temperature range
T5, T130°C: -13 .. +176 °F
[-25 .. +80 °C]
T6, T110°C: -13 .. +140 °F
[-25 .. +60 °C]
Operating temperature range
3)
T5, T130°C: -40 .. +176 °F/ -4 .. +176°F [-40 .. +80 °C / -20 .. +80°C]
T6, T110°C: -40 .. +140 °F/ -4 .. +140°F [-40 .. +60 °C / -20 .. +60°C]
Storage temperature range
-40 .. +212 °F [-40 .. +100 °C]
Fluid temperature range
3)
T5, T130°C: -40 .. +176 °F/ -4 .. +176°F [-40 .. +80 °C / -20 .. +80°C]
T6, T110°C: -40 .. +140 °F/ -4 .. +140°F [-40 .. +60 °C / -20 .. +60°C]
- Mark
EN 61000-6-1 / 2 / 3 / 4; EN 60079-0 / 1 / 31
Certificates
ATEX KEMA 10ATEX0100 X
CSA MC 224264
IECEx KEM 10.0053X
Vibration resistance to
DIN EN 60068-2-6 at 10 ..500Hz
≤
20 g
Protection class to DIN 40050
(Depending on gauge type)
IP 65 (vented gauge)
IP 69K (sealed gauge)
Other data
Supply voltage
12 .. 30 V DC
Residual ripple supply voltage
≤
5 %
Current consumption
~ 25 mA (additional switching current)
Reverse polarity protection of the
supply voltage, excess voltage
override and short circuit protection
standard
Life expectancy
> 10 million cycles (0 .. 100 % FS)
Weight
~ 300 g
Notes:
FS
(
F
ull
S
cale) = relative to the full measuring range
1)
NPN outputs on request
2)
Depending on output technology type “P” / “F” (see model code)
3)