10--8
123
Use and maintenance manual
S--20DS
Troubleshooting machine faults
PROBLEM
PROBABLE CAUSE
SOLUTION
The main switch does not work
'
Electrical supply
.
Check: phases, cables, plug,
socket.
'
Minimum voltage relay
.
Check that it is correctly sup-
plied and not burnt out.
Spindle motor will not turn
'
Electrical power supply
.
Check: the phases; the
cables; the plug; the socket.
Also check that the motor
connections are in place.
'
Motor contactor
.
Check input and output pha-
ses and check whether when
supplying A1 and A2 relay
the contactor closes.
'
Polarity change switch
.
Check input and output pha-
ses
'
Head control lever micros-
witch
.
Check that it is functioning; if
broken, replace
'
Blade tensioning
.
If the blade is not correctly
tensioned to 60 Bar, the
pressure contact does not
close and the machine is in
EMERGENCY state
'
Blade protection cover
.
Check that the closure is cor-
rect and the limit stop pres-
sed
'
Current drop
.
Check connections on the
handgrip switch, the blade
protection limiter and the
pressure gauge on the blade
tensioner group
BMT not energised (Minimum
Tension Coil)
'
Electrical power supply
.
Check: the phases; the
cables; the plug; the socket.
'
BMT Reset switch
.
Make sure that the minimum
tension coil is energised
when switch is turned from 0
to 1. If it is not, replace the
switch.
'
Emergency stop pushbutton
in
.
Make sure the emergency
stop button is released: turn
it clockwise through 1/4 of a
turn to release it.
Electropump is not working
'
Electrical supply
.
Check: phases, cables, plug,
socket and fuse no. 5 in the
electrical plant
'
No--return valve
.
Clean, if blocked replace
'
Filter
.
Clean
The pressure gauge does not
give blade tension pressure
'
Oil level
.
Top up oil level in blade ten-
sioner cylinder
'
Blocked connection
.
Check for blockages
'
Broken
.
If damaged, replace
Summary of Contents for S-20DS
Page 1: ...EN YEAR OF MANUFACTURE ______________ S 20DS USE AND MAINTENANCE MANUAL ...
Page 2: ......
Page 6: ......
Page 57: ...6 7 51 Diagrams exploded views and replace Standardised Wiring Diagrams CENELEC Standard ...
Page 58: ...6 8 52 Use and maintenance manual S 20DS ...
Page 59: ...6 9 53 Diagrams exploded views and replace ...
Page 60: ...6 10 54 Use and maintenance manual S 20DS ...
Page 61: ...6 11 55 Diagrams exploded views and replace ...
Page 65: ......
Page 68: ...6 18 61 Use and maintenance manual S 20DS Fixed worktable ...
Page 70: ...6 20 63 Use and maintenance manual S 20DS Front flywheel assembly ...
Page 72: ...6 22 65 Use and maintenance manual S 20DS Vice unit ...
Page 74: ...6 24 67 Use and maintenance manual S 20DS Driving pulley unit ...
Page 76: ...6 26 69 Use and maintenance manual S 20DS Cutting head cover ...
Page 78: ...6 28 71 Use and maintenance manual S 20DS Motor unit ...
Page 80: ...6 30 73 Use and maintenance manual S 20DS Cylinders ...
Page 82: ...6 32 75 Use and maintenance manual S 20DS Control panel ...
Page 84: ...6 34 77 Use and maintenance manual S 20DS Cylinders S 20DS ...
Page 86: ...6 36 79 Use and maintenance manual S 20DS Optional MA ...
Page 88: ...6 38 81 Use and maintenance manual S 20DS Optional Discharge side adaptor ...
Page 90: ...6 40 83 Use and maintenance manual S 20DS Optional Discharge side adaptor ...
Page 92: ......
Page 110: ......
Page 134: ......
Page 137: ......
Page 138: ......