Hyco Zen Solo Series Product Instruction Manual Download Page 2

Overview

Thank you for purchasing a Zen Solo 100°C instant boiling water tap. It replaces the need 

for a traditional kettle in the home, or counter/ wall mounted boiling water unit in the 

office. 

The Zen Solo can be installed over a sink or with the stylish, tempered glass design Zen 

Font.

Key Features

• 

Energy efficient boiling water tank.

• 

Safety lock and cool touch spout. 

• 

360° swivel spout.

• 

Pattern recognition technology to learn and predict boiling water usage.

• 

Supplied with initial scale filter for the inlet to the boiling tank.

• 

Two temperature settings 100°C and 98°C.

• 

Designed and assembled in the UK.

Always switch off the mains electricity before commencing installation.

Only connect the unit to a single-phase supply as specified on the rating plate.

Ensure tank is full of water and tap flushed through before switching power on.

The supply cord cannot be replaced by the user. If the cord is damaged the 

appliance should be returned to the manufacturer or an authorised service agent 

for replacement.

The hoses and pipes supplying this heater must not come into contact with any 

fixed wiring or the supply cord.

Do not carry the appliance by the supply cord.

1. Important Safety Points

Please fully read these instructions before commencing installation and follow to ensure 

that installation and operation are simple and safe.

2

Summary of Contents for Zen Solo Series

Page 1: ...Product Instruction Manual Zen Solo Boiling Water Tap SOLO3L SOLO6L v20 2 1...

Page 2: ...8 C Designed and assembled in the UK Always switch off the mains electricity before commencing installation Only connect the unit to a single phase supply as specified on the rating plate Ensure tank...

Page 3: ...ef valve must be tested regularly to remove scale deposits see maintenance section Water may drip from the pressure relief valve this must be piped to drain as per local relevant regulations This appl...

Page 4: ...anssion vessel Pressure relief valve Manifold Hose manifold to exp vessel Hose manifold to tank 1 5 m x 3 8 tubing fixing bracket and metal band Scale filter Hose tank to tap Zen tank Zen Solo tap Exp...

Page 5: ...2 x Black rubber washer 1 x Large and 3 x small white washer 4 x Large locking collar 2 x 1 2 BSP to 15mm 2 x 1 2 female to 3 8 PF 5...

Page 6: ...is required if the mains pressure is above 0 42 MPa 4 2 bar The Zen Solo is factory set at 100 C The temperature can be switched down to 98 C should this be desired Please see Section 6 for further in...

Page 7: ...Diagram 1 7...

Page 8: ...in a standard sink If installing in a Zen Font with Drain use the template supplied with the Zen Font to establish tap hole position The tap can be installed onto sink countertop up to 50 mm thick Pl...

Page 9: ...Diagram 2 9...

Page 10: ...allation Note the boiling tank must be located as close to the tap as practicable as it is not possible to extend hoses provided Attach M BSP to 15 mm compression fitting to offtake 1 of the manifold...

Page 11: ...tting at the bottom Mount the expansion vessel bracket to the required surface using screw pack Attach the other end of hose labelled manifold to exp vessel to expansion vessel using 1 black washer Se...

Page 12: ...n installation to secure Do not locate the filter above an electrical socket or other electrical device Step 5 Connect Mains Cold and Scale Filter The supplied scale filter is suitable for up to 300 p...

Page 13: ...ubing cut using sharp knife ensuring a clean straight cut to connect from mains supply to scale filter head inlet ensuring water flow arrow is followed Use a suitable length of 3 8 tubing to connect f...

Page 14: ...to ensure all air has been purged from the system this could take up to 1 minute Test the pressure relief valve by twisting the red cap until water flows from the valve If the pressure relief valve is...

Page 15: ...x 13 minutes to heat up from cold depending on incoming water temperature Check for signs of discharge from the pressure relief valve IMPORTANT Following the first boiling cycle it is imperative to ch...

Page 16: ...p and allow water to flow until the status ring flashes green The heater will then return to boiling shortly after If the status light begins flashing red this indicates a fault has been detected The...

Page 17: ...otate forwards Operating the Tank Once the boiling tank is installed following the correct installation instructions there should be no further operation required In the event you wish to switch betwe...

Page 18: ...removing by sliding it forward to free it from the retaining lug at the front For the 6L model unscrew the 2 crosshead screws that retain the back section and remove To change the temperature locate...

Page 19: ...3L Model PC Board Diagram 8 6L Model PC Board Diagram 9 19...

Page 20: ...e build up Failure to do so may void the warranty Regularly inspect the appliance for any signs of water leaks or damage If a leak or damage is discovered discontinue use isolate the water supply and...

Page 21: ...e sink turn upside down and drain all the water from the tank When re installing follow the original installation instructions 10 Descaling the Tank The tank should be descaled at least annually and m...

Page 22: ...e tap Scale filter needs changing Replace scale filter cartridge See Section 8 Low flow from the tap Scale build up in tank Descale tank See section 10 Low flow from the tap Aerator needs cleaning Uns...

Page 23: ...retion supply a replacement product Incorrect installation frost damage the consequences of limescale deposits or failure to follow correct operating and maintenance instructions are excluded Conseque...

Page 24: ...ing life this equipment must not be disposed of as household waste It must be taken to a local authority waste collection centre or to a dealer providing this service Disposing of electrical and elect...

Page 25: ......