Hyco Zen Solo Series Product Instruction Manual Download Page 16

Smart Technology

• 

The boiling water tank has smart technology algorithms that learn and predict 

usage: on when you need it, off when you don’t.

• 

The status ring on the base of the tap will light up red or green depending on the 

temperature of the water in the tank.

• 

The red status ring indicates the water is heating. The green status ring indicates 

the water is up to temperature and ready for use.

• 

When the heater is in a predicted non-use period (sleep mode) the status ring will 

be green and fade on and off slowly. To exit this mode, open the boiling side of the 

tap and allow water to flow until the status ring flashes green. The heater will then 

return to boiling shortly after.

• 

If the status light begins flashing red this indicates a fault has been detected. The 

unit should be isolated from the power supply and the water supply shut off before 

contacting Hyco for further advice.

Status Ring Summary

Red  

 

 

Water is heating

Green    

 

Water is up to temperature - ready to use

Fading in/ out green  

Predicted non - use period (sleep mode)

Flashing red  

 

Fault detected

5. Operation 

• 

This appliance can be used by children aged 12 plus and persons with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning the use of the appliance in 

a safe way.

16

Summary of Contents for Zen Solo Series

Page 1: ...Product Instruction Manual Zen Solo Boiling Water Tap SOLO3L SOLO6L v20 2 1...

Page 2: ...8 C Designed and assembled in the UK Always switch off the mains electricity before commencing installation Only connect the unit to a single phase supply as specified on the rating plate Ensure tank...

Page 3: ...ef valve must be tested regularly to remove scale deposits see maintenance section Water may drip from the pressure relief valve this must be piped to drain as per local relevant regulations This appl...

Page 4: ...anssion vessel Pressure relief valve Manifold Hose manifold to exp vessel Hose manifold to tank 1 5 m x 3 8 tubing fixing bracket and metal band Scale filter Hose tank to tap Zen tank Zen Solo tap Exp...

Page 5: ...2 x Black rubber washer 1 x Large and 3 x small white washer 4 x Large locking collar 2 x 1 2 BSP to 15mm 2 x 1 2 female to 3 8 PF 5...

Page 6: ...is required if the mains pressure is above 0 42 MPa 4 2 bar The Zen Solo is factory set at 100 C The temperature can be switched down to 98 C should this be desired Please see Section 6 for further in...

Page 7: ...Diagram 1 7...

Page 8: ...in a standard sink If installing in a Zen Font with Drain use the template supplied with the Zen Font to establish tap hole position The tap can be installed onto sink countertop up to 50 mm thick Pl...

Page 9: ...Diagram 2 9...

Page 10: ...allation Note the boiling tank must be located as close to the tap as practicable as it is not possible to extend hoses provided Attach M BSP to 15 mm compression fitting to offtake 1 of the manifold...

Page 11: ...tting at the bottom Mount the expansion vessel bracket to the required surface using screw pack Attach the other end of hose labelled manifold to exp vessel to expansion vessel using 1 black washer Se...

Page 12: ...n installation to secure Do not locate the filter above an electrical socket or other electrical device Step 5 Connect Mains Cold and Scale Filter The supplied scale filter is suitable for up to 300 p...

Page 13: ...ubing cut using sharp knife ensuring a clean straight cut to connect from mains supply to scale filter head inlet ensuring water flow arrow is followed Use a suitable length of 3 8 tubing to connect f...

Page 14: ...to ensure all air has been purged from the system this could take up to 1 minute Test the pressure relief valve by twisting the red cap until water flows from the valve If the pressure relief valve is...

Page 15: ...x 13 minutes to heat up from cold depending on incoming water temperature Check for signs of discharge from the pressure relief valve IMPORTANT Following the first boiling cycle it is imperative to ch...

Page 16: ...p and allow water to flow until the status ring flashes green The heater will then return to boiling shortly after If the status light begins flashing red this indicates a fault has been detected The...

Page 17: ...otate forwards Operating the Tank Once the boiling tank is installed following the correct installation instructions there should be no further operation required In the event you wish to switch betwe...

Page 18: ...removing by sliding it forward to free it from the retaining lug at the front For the 6L model unscrew the 2 crosshead screws that retain the back section and remove To change the temperature locate...

Page 19: ...3L Model PC Board Diagram 8 6L Model PC Board Diagram 9 19...

Page 20: ...e build up Failure to do so may void the warranty Regularly inspect the appliance for any signs of water leaks or damage If a leak or damage is discovered discontinue use isolate the water supply and...

Page 21: ...e sink turn upside down and drain all the water from the tank When re installing follow the original installation instructions 10 Descaling the Tank The tank should be descaled at least annually and m...

Page 22: ...e tap Scale filter needs changing Replace scale filter cartridge See Section 8 Low flow from the tap Scale build up in tank Descale tank See section 10 Low flow from the tap Aerator needs cleaning Uns...

Page 23: ...retion supply a replacement product Incorrect installation frost damage the consequences of limescale deposits or failure to follow correct operating and maintenance instructions are excluded Conseque...

Page 24: ...ing life this equipment must not be disposed of as household waste It must be taken to a local authority waste collection centre or to a dealer providing this service Disposing of electrical and elect...

Page 25: ......

Reviews: