background image

 

IMPORTANT NOTE TO THE OWNER 
This equipment is to be serviced by 
professionally trained personnel only. If this 
equipment is improperly installed, adjusted 
or altered by an unqualified person, a safety 
hazard may result.  
 
IMPORTANT NOTE TO THE SERVICER  
Read this manual and familiarize yourself 
with the specific items which must be 
adhered to before attempting to service this 
unit. The precautions listed in this manual 
should not supersede existing practices but 
should be considered as supplemental 
information.  
 
Unpacking the Unit: 
1. Cut the carton banding and open the 
carton.  
2. Remove the literature, hardware pack, 
upper Styrofoam shipping blocks, and 
Styrofoam corner posts.  
3. Remove the front assembly.  
4. Lift the unit from the remaining carton.  
5. Dispose of the cardboard and Styrofoam 
at an approved Recycle Center. Check all 
contents for damaged or missing parts. In 
case of concealed damage, notify the carrier 
as soon as possible—preferably within 5 
days. Refer to step 3 of the Transportation 
Damage section if damage or missing parts 
are noted.  
 
Operating Instructions  
Check the data specification plate and 
ensure the proper voltage and current rating 
for the type of power plug on the unit is 
available. DO NOT REMOVE THE 
GROUNDING PRONG FROM THE 
POWER CORD. See Figure 1 for the types 
of acceptable plugs. Do not use an extension 
cord for the installation of this product. 
Refer to the data specification plate for 
electrical requirements.  
 

 

• LCDI or AFCI Power Cords - Underwrites 
Laboratories and the National Electric Code 
(NEC) now require power cords that sense 
current leakage and can open the electrical 
circuit to the unit on units rated at 250 volts 
or less. In the event that unit does not 
operate, check the reset button located on or 
near the head of the power cord as part of 
the normal troubleshooting procedure.  

 

 
VOLTAGE MEASUREMENTS  
Before connecting the unit, measure the 
supply voltage. Voltage must fall within the 
voltage utilization range given in Table 1.  

 

WARNING  
To prevent electrical shock, property 
damage, personal injury, or death, do not 
remove grounding prong from plug. Follow 
all operating instructions.  
 
Installation Instructions  
To ensure that the unit operates safely and 
efficiently, it must be installed, operated, 
and maintained according to these 
installation and operating instructions and 

Summary of Contents for 52T Commercial Advantage Series

Page 1: ...his information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION Model ____________________________________________ Serial ____________________________________________ INSTALLATION INFORMATION Date Installed ________________________________________ DEALERSHIP CONTACT INFORMATION Company Name _________...

Page 2: ... for local inspector s use Observe all governing codes and ordinances NOTE TO INSTALLER Be sure to leave these instructions with the owner NOTE TO OWNER Keep these instructions for future reference Be sure to write down the model and serial number of unit on space provided on front page The model and serial number can be located on the serial number plate attached to unit UNIT INSPECTION Examine u...

Page 3: ...NEL As a professional installer you have an obligation to know the product better than the customer This includes all safety precautions and related items Prior to actual installation thoroughly familiarize of yourself with this Instruction Manual Pay special attention to all safety warnings Often during installation or repair it is possible to place yourself in a position which is more hazardous ...

Page 4: ...ing Instructions Check the data specification plate and ensure the proper voltage and current rating for the type of power plug on the unit is available DO NOT REMOVE THE GROUNDING PRONG FROM THE POWER CORD See Figure 1 for the types of acceptable plugs Do not use an extension cord for the installation of this product Refer to the data specification plate for electrical requirements LCDI or AFCI P...

Page 5: ... and must be purchased separately CHASSIS INSTALLATION The front grille can be removed for more thorough cleaning or to make the model and serial numbers accessible To remove pull the filter out and remove the two grille screws Pull the grille out from the bottom and lift up from the tabs on the top of the case 2 Remove the grounding screw and wire next to the grounding symbol on right side of cha...

Page 6: ...h the tabs on the case and snap into place Replace the screws and filter Refer to Page 4 Figure A VENT CONTROL AND AIR DIRECTION See Figure E The vent control is located behind the front grille on the right side of the air discharge area When set at CLOSE only the air inside the room will be circulated and conditioned When set at OPEN some inside air is exhausted outside To open or close the vent ...

Page 7: ...es or other objects do not block air flow to and from the unit If air is obstructed and or deflected back into the unit the air conditioners compressor may cycle on and off rapidly This could cause damage to the compressor Wiring Before wiring the unit please review the following warnings and cautions WARNING To avoid the risk of electrical shock personal injury or death do not service this unit w...

Page 8: ...unattended air conditioner may result in extreme heat in the conditioned space causing overheating or death of persons or animals Take proper precautions to avoid unattended operation Air Conditioner Features ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions Then follow the symbol for th...

Page 9: ...e that there are no obstructions between receiver and remote controller don t drop or throw the remote control don t let any liquid in the remote control and put the remote control directly under the sunlight or any place where is very hot ...

Page 10: ...eneral use remote controller it could be used for the air conditioners with multifunction for some function which the model doesn t have if press the corresponding button on the remote controller that the unit will keep the original running status ...

Page 11: ...room temperature automatically to select the suitable running method and to make ambient comfortable About LOCK Under switch on or switch off state you may hold and key simultaneously to lock and unlock the keypad When locked the display will show the LOCK icon in which case the lock icon will flash three times upon operation of any key After the keypad is unlocked the lock icon on the display wil...

Page 12: ...itioner Features continued Note Tap or hold either up or down v button until the desired temperature is seen on display This temperature will be automatically maintained anywhere between 61F 16 C and 86F 30 C for both cooling and heating modes If you want the display to read actual room temperature select the fan only mode Note The fan speed to automatically set to the speed needed to provide opti...

Page 13: ...ps previously set temperature and fan speed Temperature display set temperature no display if power turn off Press Timer once LED display remaining time of set time LED return to set temperature by 5 seconds When in Fan Only mode LED only display room temperature do not display set temperature Turning the unit ON or OFF at any timer will cancel the Delay Start Stop function The delay Start Stop fe...

Page 14: ...14 Air Conditioner Features continued ...

Page 15: ...ual If the unit is operated in a dusty climate dust may collect in the basepan and clog the condenser coil It is advisable to remove the unit from the sleeve and thoroughly clean the basepan and condenser coil on a periodic basis If the unit is installed ocean side or in a corrosive atmosphere its life may be greatly reduced by the corrosive environment Under these conditions the unit should be re...

Reviews: