http://www.hybertone.com COIP CDMA Voice Gateway
15
This parameter value ranges from 60ms to 120ms and the default value is 80ms. When the
value of this parameter is increased properly, the repeated DTMF can be avoided efficiently.
However, the packet loss may also be caused.
3.3.4 Automatic Setting
If the service provider provides the automatic setting, you can select
“
Enable
”
to start the
automatic setting feature and enter the address of the server. If the service provider does not
provide the automatic setting, you need to select
“
Disable
”
to speed up the startup time of the
COIP.
It is a special server, which needs the support of the specific system.
3.3.5 Setting of the Remote Control
Press *20# on the terminal to initiate the request to realize the remote management of
equipment. The remote control server is provided by the service provider. The default port is
1920 and the terminal is identified by the SN. The remote control password is identical with
that of the server and is set as default.
In the following figure, the remote control server is set as 202.155.200.154. The terminal user
presses *20# and a long tone is heard, which indicates that the instruction has been
successfully sent. The remote administrator access
http://202.155.200.154:8086
and the model
and SN of the gateway are displayed. Click the gateway SN to set the remote gateway.
Note: It is a special server, which needs the support of the specific system. For details, please contact the