Turn the knob COUNTERCLOCKWISE to "S"
and press the start button. If the rotator unit stops
before the South position and the indicator light
turns off, adjust the "CCW end of rotation" shaft
counterclockwise as far as it will go. The adjust-
ments for end of rotation are located on the
bottom side of the control box. Turn the unit to
"W", stop, then again back to "S", using the
method as described previously. If the control
light remains on this time, slowly turn the "CCW'
shaft clockwise until the light goes off.

Turn the knob CLOCKWISE to "S" and press the
start button. The rotator unit should turn
clockwise toward the "South" position. If the
rotator stops before reaching the "South"
position and the indicator light turns off, adjust
the "CW end of rotation" shaft clockwise as far
as it will go. Turn the unit to "E", stop, then
again back to "S". If the light remains on, slowly
turn the "CW' shaft counterclockwise until the
light turns off.

Leave the rotator in the full clockwise (South)
position for installation. Disconnect the power
plug and remove the 5-wire cable from the
control unit. Note the wire colors before
removing.

WARNING:

Metal masts and towers must be placed so
that if they fall, they cannot contact power
lines, be a hazard to individuals, or
endanger property! Antennas, masts, and
towers are conductors of electricity. If the
antenna, mast or tower comes in contact
with power lines, you can be electrocuted!

Summary of Contents for AR-40

Page 1: ... a heavier gauge wire The control unit must be placed inside the house or other protected location The maximum voltage produced by the control unit is 18 VAC Before mounting the rotator unit on your mast or tower check the operation with the control unit and cable Strip all conductors at both ends of the cable and attach to the terminals Connect terminal 1 to terminal 1 etc On the control box simp...

Page 2: ... toward the South position If the rotator stops before reaching the South position and the indicator light turns off adjust the CW end of rotation shaft clockwise as far as it will go Turn the unit to E stop then again back to S If the light remains on slowly turn the CW shaft counterclockwise until the light turns off Leave the rotator in the full clockwise South position for installation Disconn...

Page 3: ... the mast for strain relief Mast guy wires may be attached to the rotator s lower mast support Attach the upper mast to the rotator unit and secure Install the antenna on the upper mast pointing South The feedline rotation loop should allow for complete CCW rotation Route the 5 wire cable to the control unit and connect as before Check the operation of the rotator system as in the pre installation...

Page 4: ...dy pre drilled A large hole must also be drilled or cut for control cable access Tighten the four bolts but not to the final tight ness Observe how the rotator turns It must rotate the mast within the thrust bearing or guide tube without binding If binding occurs either move the rotator slightly on the rotor plate or add shims between the mast and the upper mast support The maximum O D of the mast...

Page 5: ...ude a copy of your sales receipt For out of warranty units call the Customer Service Department for prices and shipping authorization Hy gain 308 Industrial Park Road Starkville Mississippi 39759 USA The price includes rebuilding the unit replacing all defective and or worn parts and return freight charges Hy Gain reserves the right to change prices at its option when returning items for re pair a...

Page 6: ...no warranty is given or implied and no liability is assumed by Hy Gain as to its accuracy or completeness Changes maybe made from time to time so the user should verify all factors tht may be critical This information is not to be construed as to authorizing or advising use of any patented invention ...