SECTION 4 | TECHNICAL REFERENCES
4-3
Problem with controller internal voltage. Controller may need to be replaced.
4-4
Battery supply is too low or too high.
Make sure batteries afe fully charged.
Do not operate while charging.
4-5
Joystick signal problem.
Wiring problem-check for short circuits, misconnection, check P15-12 connection.
6-x
There is a problem with the height measurements, or the elevation switch disagrees with the
height sensor.
Check that the output from height sensor (P12-12) is in range (between 0.5V and 4.5V)
6-1
Problem with angle sensor or its connections
6-2
This feature does not apply on ANSI/CSA models.
6-3
Problem with elevation switch or its connections
6-6
This feature does not apply on ANSI/CSA models.
7-x
There is a problem with the power wiring – the voltage on the B+ stud is too low
Check for a short-circuit to the B+ stud
7-1
Motor A current too high.
7-2
Motor A current too low.
7-3
Motor B current too high.
7-4
Motor B current too low.
7-5
Check drive connections at both drives--short or multiple wiring faults.
7-7
Check B+ stud connections on controller. Voltage is too low.
MAINTENANCE & TROUBLESHOOTING