![HWR InoFlex VF016 Operating Manual Download Page 36](http://html1.mh-extra.com/html/hwr/inoflex-vf016/inoflex-vf016_operating-manual_2190654036.webp)
5
Maintenace
Page 5-28
InoFlex
®
VF016 - VF026
© Copyright
Edition C
HWR Spanntechnik GmbH
EN
5.3
D
ISASSEMBLY
/
CLEANING
/
RE
-
ASSEMBLY OF THE CENTERING VICE
To ensure proper clamping force, the centering vice must be disassembled
at regular intervals, cleaned and greased again.
Note
Disassembly and cleaning intervals see table 5-4 on page Fehler!
Textmarke nicht definiert..
Disassembly and cleaning
Step 1
Place the centering vice on a suitable underlay so that the
screws (2) are accessible. (If need be use eyebolts and hoist)
Step 2
Loosen and remove the screws (2).
Step 3
Place the centering vice on a suitable underlay so that the
screws (12) are accessible. (If need be use eyebolts and hoist)
Step 4
Loosen and remove the screw (12).
Step 5
Lift off the upper housing (9) of the InoFlex
®
centering vice from
the lower housing (7).
Step 6
Loosen and remove the cylinder pins (6).
Step 7
Remove the seal kit (4), shaft seal (5) and O-Ring (3) as one
unit. Check the condition and function of the shaft seal (5). (If
necessary, replace the shaft seal before reinstalling the In-
oFlex
®
centering vice.)
Step 8
Pull out the pivot bolt (1).
Step 9
Lift out the entire parallel slide unit (8) by gently lifting and tilting
it.
Step 10
Remove the base jaws (10 u. 11).
Step 11
Clean all the centering vice's components. Use a cold cleaner if
necessary.
Step 12
Check all the components. Damaged parts must be replaced.
Contact the manufacturer if you have any questions.
Summary of Contents for InoFlex VF016