Title
Rev.
Page
HMK-825 HMC-825
Ver1.5
P.50/65
DC3+’i’
[Name] Cutting after it detects the black mark.
[Format] ASCII DC3 i
Hex 13 69h
Decimal 19 105
[Descript] - The value is not deleted until the next value is changed, even though power off.
If you register the information at SW1,SW2, the black mark detects automatically,
Then it cuts the registerd points.
- Please use the given program - ‘memory swtich setting utility program’.
- Please refer the 2-8)
SUB+’t’+n
[Name]
Retractor - automatic collection time & valid / invalid
[Format]
ASCII
SUB t n
Hex
1A 74h n
Decimal 26 116 n
[Range]
0
≤
n
≤
255
[Initial] n=10( It means it will be collected 10 seconds later.)
[Descript]
The collection time fixes according to the second time.
The automatic collection will be invalid, once n is 0 (zero).
SUB+’r’
[Name]
Retractor – manual collection
[Format] ASCII
SUB r
Hex
1A 72h
Decimal 26 114
[Descript]
It collects the printed paper.
It doesn’t collect the paper automatically.
It is to collect the paper, when the user want the collection.
SUB+’1’
[Name]
Line 1 (Vertical, Horizontal)
[Format] ASCII SUB
1
Hex
1A
31h
Decimal
26
49
[Descript] It chooses the line 1 of vertical, horizontal.