20
Guarantee
The guarantee does not cover damage due to insufficient maintenance!
Maintenance Warnings
If a maintenance warning goes off, you can continue using the wood-burning stove, but contact your dealer
as soon as possible. Your stove could be affected by impure combustion.
o
pErAtionAl
problEMS
Blackened glass
• The wood is too damp. Only use wood stored for at least 12 months under cover and with a moisture
level not exceeding 18% RH.
• The door gasket may be leaking.
Smoke in the room when opening door
• The grate in the chimney may be closed. Open the grate.
• Insufficient chimney draft. See section on chimney or contact chimney sweep.
• Soot door leaking or dislodged. Replace or refit.
• Never open the door when there are still flames on the wood.
Uncontrollable combustion
• Faulty seal in door. Fit new seal.
Safety Alarms
In case the safety alarms go off, you must not use the stove. Contact your dealer as soon as possible.
At interruptions that you cannot yourself rectify, you should contact the dealer.
d
EclArAtion
oF
p
ErForMAncE
The DoP can be downloaded from our website via the following links:
HWAM 3630 with Autopilot IHS
TM
: www.hwam.com/dop/3630ihs-3650ihs
HWAM 3650 with Autopilot IHS
TM
: www.hwam.com/dop/3630ihs-3650ihs
HWAM 3640 with Autopilot IHS
TM
: www.hwam.com/dop/3640ihs-3660ihs
HWAM 3660 with Autopilot IHS
TM
: www.hwam.com/dop/3640ihs-3660ihs
Summary of Contents for Autopilot IHS 3630
Page 2: ......
Page 4: ...4 A A1 A2 1 2 3 4 3 4 1 B B2 1 2 3 4 6 5 1 2 3 4 6 5 B1 ...
Page 5: ...5 C 1 2 3 5 4 6 6 7 8 9 11 12 10 C1 C2 4 6 6 7 14 13 3 9 10 D1 4 3 5 1 2 ...
Page 6: ...6 E E1 ...
Page 7: ...7 F ...
Page 8: ...8 ...
Page 33: ...33 ...
Page 46: ...46 ...
Page 47: ...47 ...
Page 48: ...www hwam com ...