54
8. Wiring-as shown
Section 14 State Sequence Test
This procedure continuous output for plurality states at a given time, starting from the
initial state until the end state, 20 states the most. State types can be divided into : no-load ,
any ; AN , BN, CN ; AB, BC , CA ; ABN , BCN , CAN and ABC . The initial state and the end
state are fixed to be no - load state or any state, if choose any state, can set each phase
current value, voltage value and phase in the status bar on the right.
1. [State insert]
Summary of Contents for HT-802