Excelon XD/XQ Operator
’s Manual
91
•
How to setup frame fitting values
(1) Trace the frame with Frame Reader
(2) Execute the edging process with Mid-Index Lens (low diopter lens preferred)
and carry out the fitting with the edged lens.
(3) In case the edged lens is bigger than the frame, adjust the value to
‘-‘ (minus).
In case the edged lens is smaller than the frame, adjust the value to
‘+’ (plus).
•
Input each size variation value to all the frame material. (Input horizontal value
and vertical value separately)
•
Remember that these adjusted values are applied in diameter. (unit : mm)
•
Using the
“Master Size”, the operator can set up the adjustment value for all
frame materials simultaneously.
•
To input right and left frame fitting value separately, turn on the
“Separate
Frame Fitting R/L
” option.
!
NOTE