7
CONTROL PANEL – UKU
With a wooden housing
• Remove the back cover of the UKU control panel to attach it to
the wall.
• Attach the back cover to the wall so that the upper edge of the
control panel is at eye level.
• Connect the power cable with the screw terminal of the device.
• Attach the device to the back cover that has been placed on the
wall. Secure it with screws from the sides.
With a plastic housing
• Connect the power cable with the cable screws of the UKU control
panel.
• Pull off the control panel control knob.
• Attach the device with screws to the wall.
• Replace the control knob to the control panel.
MAIN MODULE
• When installing inside the steam room, the enclosure should be
placed 4-19.7 in (10-50 cm) above the floor.
• Fix the unit to the wall with 4 screws.
• Do not attach the main module to the ceiling or inclined surfaces.
• Connect the cables of the UKU control panel, temperature sen-
sor, and door switch through a cable gland to the enclosure and
main module, see figure.
• Connect the power cable (240V 2(N)~) of the control console
through the cable glands to the main module, see figure.
DOOR SENSOR
The door switch consists of two parts: a sensor and a magnet.
• Connect the cable ends to the terminals of the switch.
• Secure the magnet to the door. It must allow the door to close
and pass directly by the doorpost.
1
2
3
Summary of Contents for UKU LOCAL
Page 1: ...HEATER REMOTE CONTROL UKU WiFi LOCAL T L COMMANDE D APPAREILDE CHAUFFAGE FR 800827...
Page 2: ......
Page 5: ...5...
Page 16: ...16...
Page 19: ...19 FR...
Page 31: ...huumsauna www huumsauna com...