Connecting the sauna stove with the chimney
•
The flue gas outlet of HUUM sauna stoves is at the top of the
sauna stove. The sauna stove is connected to the chimney using
special metal flue pipes, which are optionally sealed with heat-
resistant sealing rope.
• The elbows of the connection tubes must be smooth to keep
draught loss to a minimum.
• The tube is inserted through the wall of the chimney and sealed
with mineral wool.
• The sauna stove can only be connected to the chimney by
specialists.
•
The flue gases of the stove must be directed into a separate flue.
Use of a common flue with other furnaces is not permitted.
ATTENTION!
Forced extract ventilation may cause problems with the
ventilation of the room and inadequate furnace combustion, therefore,
designing and building such a ventilation system is permitted only with
the supervision of a licensed specialist.c