• If the stove is installed in a niche composed of non-combustible
material (stone, concrete), at least 100 mm should be left
between the wall and the stove for air movement.
• The safety distance for combustible materials can be reduced
to 1/2 in the case of a single and 1/4 in the case of a double heat
barrier. The heat barrier is considered within the safety distance,
and the diff erence between the outer surface and the protected
area must be at least 30 mm.
• The sauna stove must be installed on a non-combustible
surfacen (min. 60 mm) with the required carrying capacity.
•
Electrical equipment and wiring are not permitt ed in the safety
area the sauna stove.
Table 1
Power
kW
Room
m
3
A
mm
B
mm
C
mm
D
mm
E
mm
F
mm
Ø
mm
H
mm
HIVE Heat 12
12
6-13
170
500 240 425
5
300 450 750
HIVE Heat 12 LS
12
6-13
170
500 240 425 155 340 450 750
Table 1
Power
kW
Room
m
3
A
mm
B
mm
C
mm
D
mm
E
mm
F
mm
Ø
mm
H
mm
HIVE Heat 12
12
170 500 240 425
5
300 450 750
HIVE Heat 12 LS
12
170 500 240 425 155 340 450 750
Min. 1200 mm
C
B
A
A
A
E
F
D
60 mm
Ø
H
Summary of Contents for HIVE Heat
Page 51: ...51...
Page 52: ...NOTES M RKMED MUISTIINPANOT ANMERKUNGEN ANTECKNINGAR UWAGI All rights reserved HUUM 2022...
Page 53: ...NOTES M RKMED MUISTIINPANOT ANMERKUNGEN ANTECKNINGAR UWAGI All rights reserved HUUM 2022...
Page 54: ...NOTES M RKMED MUISTIINPANOT ANMERKUNGEN ANTECKNINGAR UWAGI All rights reserved HUUM 2022...
Page 55: ...NOTES M RKMED MUISTIINPANOT ANMERKUNGEN ANTECKNINGAR UWAGI All rights reserved HUUM 2022...
Page 56: ...huumsauna www huum eu...