6. Electrical
Standard Case Wire Color Code
Ground
Anti-Sweat
Lights
Receptacles
T-Stat/Solenoid 230VAC
T-Stat/Solenoid 115VAC
T-Stat/Solenoid 24VAC
Fan Motors
Blue Condensing Unit
Green
Purple
Orange
Yellow
Red/Black
White/Black
Red/White
Brown
Use Copper Conductors Only
430-01-0338 R101003
Color Decsription
Color
CASE MUST BE GROUNDED
NOTE: Refer to label illustrated above that is affixed to case to
determine the actual configuration as checked in the
“TYPE INSTALLED” boxes.
ELECTRICAL CIRCUIT IDENTIFICATION
Standard lighting consists of fluorescent lamps on hot cases
and LEDs on refrigerated cases, located within the case at
the top.
Lights switches are located behind the front doors on hot
cases and on the canopy for refrigerated cases.
ELECTRICAL SERVICE RECEPTACLES
(When Applicable)
The receptacles located on the exterior of the merchandiser
are intended for scales and lighted displays. They are not
intended nor suitable for large motors or other external
appliances.
DO NOT place Self Contained versions
of this case, having the electric evaporator pan,
underneath or adjacent to any flammable structure
or structure housing flammable merchandise!
DANGER
FIELD WIRING AND SERIAL PLATE
AMPERAGE
Field Wiring must be sized for component amperes printed
on the serial plate. Actual ampere draw may be less than
specified. Field wiring from the refrigeration control panel to
the merchandisers is required for refrigeration thermostats.
Case amperes are listed on the wiring diagram, but always
check the serial plate.
BALLAST LOCATION
Ballasts/Drivers are located under the case in a electrical box.
Electrical Wiring Diagrams
Due to the Custom nature of these case, the wiring diagrams and loads are appended to each guide. For
additional copies, please contact the factory. Have the unit serial number available.