52
– English
MAINTENANCE
Removing the BioClip Plug (Combi)
To change a Combi unit from the BioClip function to
a cutting unit with rear ejection, remove the BioClip
plug, which is located under the unit, attached with
three screws.
1. Put the unit in the service position, see ”Placing
in the Service Position”.
2. Remove the three screws holding the BioClip
plug, and remove the plug.
3. Tip: Fit three full-thread screws M8x15 mm in
the screw holes to protect the threads.
4. Return the unit to the normal position.
Fit the BioClip plug in the reverse order.
Removal of BioClip plug