6
FORK, TRIPLE CLAMP
30
201701-11
201700-11
- Pull out the piston rod and push it back in numerous times while pressing it to
one side slightly.
✓ Air bubbles emerge and the cartridge is bled.
- Keep bleeding until no more air bubbles emerge.
✓ The piston rod moves out automatically to the middle of the total stroke
distance.
•
Info
I
When fully bled, the correct air chamber length is achieved automatically.
- Position spring.
- Pull the spring down. Mount screw cap@).
•
Info
I
When assembling, ensure that the screw caps are correctly mounted
according to the hydrostop needles.
Rebound damping side - red hydrostop needle, screw cap with
mark
REB.
Compression damping side - silver hydrostop needle, screw cap with
mark
COMP.
- Pull the spring down. Mount the open end wrench on the hexagonal part.
- Hold the open end wrench. Tighten screw cap@).
Guideline
I
Screw cap on piston rod
I
Special socket (T14047) (
�
p. 276)
- Push the outer tube up.
I
M8x0.75
- Clamp the outer tube in the area of the lower triple clamp.
I
Clamping stand (T1403S) (
�
p. 276)
- Tighten screw cap
fD.
Guideline
I
Cartridge on outer tube
I
Special socket (T14047) (
�
p. 276)
I
M51x1.5
- Mount the adjuster. Mount and tighten screw
@).
Guideline
I
Screw, adjuster
I
M4x0.5
Alternative 1
118 Nm (13.3 lbf ft)
I
I
40 Nm (29.5 lbf ft)
I
12.5 Nm
(1.84 lbf ft)
- Turn the adjuster of compression damping Gi) (mark
COMP)
and the adjuster
of rebound damping
G,
(mark
REB)
all the way clockwise.