9.25
SHOCK ABSORBER, LINK FORK 9
Info
The floating piston must be positioned at exactly this
point when the rod is fully extended; otherwise,
damage will occur during compression of the shock
absorber.
- Remove the special tool.
Remove adapter
O
from connector
8
of the vacuum
pump.
Info
Hold the damper so that the filling port is at the high
est point.
- Remove the adapter.
- Mount and tighten screw
@).
Guideline
I
Screw, filling port
I M10x1
14 Nm (10.3 lbf ft)
- Mount screw
O
with the O-ring and screw in approx. 2 full
turns, but do not tighten it fully.
Info
The piston rod is fully extended.
- Fix the special tool in the vise.
Filling tool (T170S1)
(
0
p. 325)
Filling adapter (T1296)
(
0
p. 322)
...
- Connect the special tool to the pressure regulator of the filling
cylinder.
I
Filling gas - nitrogen
- Adjust the pressure regulator.
Guideline
I
Gas pressure
I
1 0 bar (145 psi)
- Position the damper in the special tool.
✓ The hexagonal part of tap handle
6)
engages in the
hexagon socket of the filling port screw.
- Open filler tap G).
- Fill the damper for at least 15 seconds.
Guideline
I
Gas pressure
I
1 0 bar (145 psi)
81