To apply grease to the two-piece
shaft
• Apply grease to the end of the drive shaft after
each 30 hours of operation.
Troubleshooting
The engine does not start
Check
Possible cause
Procedure
Stop switch.
The stop switch is in the stop posi-
tion.
Let an approved service agent re-
place the stop switch.
Fuel tank.
Incorrect fuel type.
Drain the fuel tank and fill with cor-
rect fuel.
Spark plug and cylinder.
The spark plug is dirty or wet.
Make sure that the spark plug is
dry and clean.
The spark plug electrode gap is in-
correct.
Clean the spark plug. Make sure
that the electrode gap is correct,
Technical data on page
23
. Make sure that the spark plug
has a supressor.
The spark plug is loose.
Tighten the spark plug.
Engine is flooded because of re-
peated starts with full choke after
ignition.
Remove and clean the spark plug.
Put the product on its side with the
spark plug hole away from you.
Pull the starter rope handle 6-8
times. Assemble the spark plug
and start the product. Refer to
start a cold engine on page 14
.
The engine starts but stops again
Check
Possible cause
Procedure
Fuel tank
Incorrect fuel type.
Empty the fuel tank and fill it with
correct fuel.
Fuel filter
The fuel filter is clogged.
Replace the fuel filter.