GROUNDING REQUIREMENTS

This power unit must be grounded. If it should malfunction or breakdown, grounding 
provides a path of least resistance for electric current to reduce the risk of electric shock. 
This power unit has a power cord of at least 1.65 m (5.4 ft) in length and is equipped with a 
grounding conductor and grounding plug. The plug must always be inserted directly into an 
electrical outlet that is properly installed and grounded in accordance with all local codes and 
regulations.

DO NOT USE AN EXTENSION CORD

.

WARNING:

Improper connection of the equipment grounding conductor can 

result in a risk of electric shock. Check with a qualified electrician 

or service person if you are in doubt as to whether the outlet is 

properly grounded. Do not modify the plug provided with the 

power unit – if it will not fit the outlet, have a proper outlet 

installed by a qualified electrician.

The unit has a grounding attachment plug. Make sure that the 

power unit is connected to an outlet having the same configuration 

as the plug. No adapter should be used with this power unit. The 

power unit should be connected to an independent circuit breaker.

ELECTRICAL REQUIREMENTS

This appliance is for use on a nominal circuit of 15 A at 110-120 Volts A.C. and 60 Hz.

G

eneral

 

Guidelines

 

to

 

be

 

observed

 

at

 

all

 

times

1� 

The power unit must be installed in a ventilated area away from any 

heat source;

2� 

The Husky central vacuum system must be used only on dry 

surfaces. At no time should the system be used to draw up liquids 
nor should it be used to vacuum wet carpets or floors;

3� 

It is mandatory that the filtration cage be equipped with its 

permanent filter at all times when the system is in use;

4� 

The motor housing must never be obstructed in any way to avoid 

overheating or damaging;

5� 

DO NOT vacuum gypsum dust, flour, mud, or any sludgy materials 

as they will cake onto the filter and obstruct the filtration system 
resulting in the overheating of the motor and thus failure of the 
power unit to function properly;

6� 

Do not attempt to shorten or modify the electrical power cord;

7� 

As a security measure, unplug the electrical power cord before 

proceeding with any maintenance;

8� 

In order for the warranty to be valid, only a Husky authorized service 

personnel may carry out the necessary repairs or maintenance on 
the motor;

9� 

The warranty will be void if non-recommended products such as 

filters or any other after-sale parts as carbon brushes and motors 
are used to repair the unit. Husky recommends strongly to use only 
Husky certified filters and replacement part;

10� 

Power unit must be positioned so that the plug is always easily 

accessible;

11� 

Pertaining to an electrified inlet valve (intended for the connection 

of a current-carrying hose/motorized nozzle combination):

•  Connect only a current-carrying hose to this wall valve;
•  Do not install a wall valve outdoors;
•  Do not use with a damaged hose; return hose to a service centre.

IMPORTANT

Husky is not responsible for damages resulting from improper 

use. The warranty does not cover damage resulting from misuse 

or problems resulting from installation that does not conform 

to specifications, or any functional alterations and / or physical 

changes to the power unit. Improper or non-recommended 

installation of the system and / or power unit done against 

predefined principles of the user manual is also considered misuse.

All conditions and restrictions are set forth in the Husky limited 

warranty, the user manual and the system installation guide. To 

optimize the performance and life of your Husky power unit, it is 

important to do regular maintenance and cleaning of the filter 

according to the guidelines listed in this user manual.

2. GENERAL GUIDELINES AND REFERENCE

Summary of Contents for SOLSTICE

Page 1: ...EN DOC 630 REV01 CentralVacuum System USER MANUAL 2000868 Conforms to UL Std 1017 Certified to CAN CSA Std C22 2 No 243 10 Made in Canada this manual applies to HUSKY SOLSTICE...

Page 2: ......

Page 3: ...EMENTS 5 GENERAL GUIDELINES TO BE OBSERVED AT ALL TIMES 3 MODEL 6 4 INSTALLATION 6 POWER UNIT 6 5 LOW VOLTAGE WIRE CONNECTION 7 6 SYSTEM OPERATING INSTRUCTIONS 7 7 SYSTEM MAINTENANCE 7 FILTRATION SYST...

Page 4: ...that the plug remains removed for commercial use models Do not pull or carry by power cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Checkinletopeningsforsm...

Page 5: ...y way to avoid overheating or damaging 5 DO NOT vacuum gypsum dust flour mud or any sludgy materials as they will cake onto the filter and obstruct the filtration system resulting in the overheating o...

Page 6: ...ough to be screwed to at least 2 studs Fasten the mounting bracket to the mounting board with the provided screws 3 Concrete wall Drill the holes with a concrete drill bit Insert the provided wall anc...

Page 7: ...er part of the filtration bag on the plastic air inlet 6 Put the unit s cover back in place NOTE When replacing the filtration bag make sure that the extendible rubber part of the filtration bag is ne...

Page 8: ...Repeat for each vacuum inlet NOTE If all vacuum inlets are functional and your flexible hose is a low voltage technology handle then there may be a defect in the cut off switch of the hose or the hose...

Page 9: ...If you have any comments or suggestions related to our products or distributors please contact us For any inquiries Call us at 450 622 9000 1 800 361 3965 E mail us at info nuera air com Send us your...

Page 10: ...instructions of the system are not followed To get maximum benefit from your central vacuum system and to keep the warranty valid Husky recommends a regular replacement of the filter and adhering to t...

Reviews: