background image

8 | DOC-630-HU EN REV01 | 2019�06�07 

ORIGINAL INSTRUCTIONS

8. TROUBLESHOOTING

Failure of the power unit could be caused by:

•  Inadequate power level (voltage / amperage) (ensure that power level complies with the power unit’s electrical requirements);
•  Malfunction of the motor or control module.

Simple checks can often help you find out why your power unit is inoperative. We invite you to verify the following before calling a service technician.

S

ituation

V

erification

NO POWER

Check that the power unit’s electrical cord is plugged directly into a power outlet.

The power unit is equipped with a mini breaker (button on the side of the motor housing) which protects the motor against an overload. To reset the mini breaker, simply 
push the button. If the power goes off one more time, call a service centre near you.

Using a screwdriver fitted with a rubber handle, touch both pins of the low voltage terminals (short circuit the 2 pins) on the side of the motor housing. If the power unit 
starts, the problem lies with the low voltage wiring (installed along the piping).
You should then verify if the 24 V circuit is adequately connected by checking each inlet. Open the inlet cover, touch the small contacts with the head of a pair of metal 
pliers with rubber handles. This will establish power and start the motor. Repeat for each vacuum inlet.

NOTE

 

»

If all vacuum inlets are functional and your flexible hose is a low-voltage technology handle, then there may be a defect in the cut-

off switch of the hose or the hose itself�

Check the breaker on your electric circuit panel.

DECREASED 

SUCTION

The flexible hose may be blocked. If you cannot unblock it, try inserting the opposite end of the hose into the wall inlet; touch the contacts which are located on the inside 
of the inlet with the hose wand in order to start the power unit.

NOTE

 

»

Frame the inlet with your hands or a large enough piece of cloth (such as a towel) to ensure the maximum suction to unblock 

the hose�

Check that the cover on the unit is well in place and that the gasket is in good condition.
Check if the disposable filtration bag needs to be replaced.
Make sure all inlets are airtight.
If the pipes are visible in certain areas: check if the fittings are well glued and that there are no air leaks.

If the pipes should be blocked behind the walls, it is possible to determine where the blockage is located by starting from the furthest inlet from the central vacuum. Insert 
a tissue paper and check to see if the tissue paper reaches the dust canister. Repeat the same for each inlet.

LED INTERPRETATION GUIDE 

All Husky power units with internal control module come with an explicative sticker (inside the module casing cover where 
applicable).

NOTE

 

»

The indicator in step 4 will not appear on this power unit model�

Fig. 3 

LED interpretation guide

Summary of Contents for SOLSTICE

Page 1: ...EN DOC 630 REV01 CentralVacuum System USER MANUAL 2000868 Conforms to UL Std 1017 Certified to CAN CSA Std C22 2 No 243 10 Made in Canada this manual applies to HUSKY SOLSTICE...

Page 2: ......

Page 3: ...EMENTS 5 GENERAL GUIDELINES TO BE OBSERVED AT ALL TIMES 3 MODEL 6 4 INSTALLATION 6 POWER UNIT 6 5 LOW VOLTAGE WIRE CONNECTION 7 6 SYSTEM OPERATING INSTRUCTIONS 7 7 SYSTEM MAINTENANCE 7 FILTRATION SYST...

Page 4: ...that the plug remains removed for commercial use models Do not pull or carry by power cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Checkinletopeningsforsm...

Page 5: ...y way to avoid overheating or damaging 5 DO NOT vacuum gypsum dust flour mud or any sludgy materials as they will cake onto the filter and obstruct the filtration system resulting in the overheating o...

Page 6: ...ough to be screwed to at least 2 studs Fasten the mounting bracket to the mounting board with the provided screws 3 Concrete wall Drill the holes with a concrete drill bit Insert the provided wall anc...

Page 7: ...er part of the filtration bag on the plastic air inlet 6 Put the unit s cover back in place NOTE When replacing the filtration bag make sure that the extendible rubber part of the filtration bag is ne...

Page 8: ...Repeat for each vacuum inlet NOTE If all vacuum inlets are functional and your flexible hose is a low voltage technology handle then there may be a defect in the cut off switch of the hose or the hose...

Page 9: ...If you have any comments or suggestions related to our products or distributors please contact us For any inquiries Call us at 450 622 9000 1 800 361 3965 E mail us at info nuera air com Send us your...

Page 10: ...instructions of the system are not followed To get maximum benefit from your central vacuum system and to keep the warranty valid Husky recommends a regular replacement of the filter and adhering to t...

Reviews: