background image

OPERATING INSTRUCTIONS

C

CU

UT

TT

TIIN

NG

G::

MAINTENANCE AND INSPECTION

5

http://www.huskietools.com

[email protected]

R

RIIG

GH

HT

T

W

WR

RO

ON

NG

G

1.  Daily maintenance is required to ensure that the tool is kept in good working condition.

2.  Sharpen blades occasionally with a sharpening stone on the back side of the blades to remove any

burrs that may occur.

3.  Do not store the tool in a humid environment.

4.  Wipe away any excess oil with a soapy cloth.

5.  Provided that maintenance of the tool is carried out regularly, the tool should provide many years of

service.

6. 

Should you experience any difficulty with the operation and maintenance of this tool, contact Huskie’s

technical support department at 1-800-860-6170.

5.  Continue to advance the blades until the material is cut. If material is cut and tool has not yet

bypassed, it may be difficult to retract blades. If this occurs, continue to advance tool and build pressure.
A series of clicks will be heard while the tool running in a “neutral” mode. This indicates that the tool has
built full pressure and bypassed and can now be released.

1.  Retract blades by pressing the release button.

2.  Make sure that material being cut is within the specified cutting capacity of the tool.

3.  Place the material to be cut between the blades and press the advance trigger until blades hold the

material in place.

4.  Check material for proper alignment to the cutting blades. It should be at a 90° degree angle to the

blades. Any other angle will cause the blades to spread apart and possibly break.

Summary of Contents for REC-585YC

Page 1: ...Operating Instruction Manual REC 585YC Battery Powered Cutting Tool with Parts List ...

Page 2: ......

Page 3: ...IS SS SO OR R T TY YP PE E C CU UT TT TE ER R 3 3 3 3 J JA AW W O OP PE EN NI IN NG G For Copper Aluminum 3 3 Jaw Opening Cuts up to 1000 MCM CU Large 9 Ton Output 180 Degree Swivel Head Battery Cartridge BP 70EI BP 70MH DC Charger CH 70DCH Battery Cartridge BP 70E Battery Charger CH 35R Carrying Case REC 5000CASE Input voltage 120V AC single phase Charging Capacity 20VA Dimensions 7 5 L x 4 5 W x...

Page 4: ...tools com info huskietools com STANDARD ACCESSORIES OPTIONAL ACCESSORIES BATTERY CARTRIDGE BP 70E BATTERY CHARGER CH 35R CARRYING CASE REC 5000CASE DC CHARGER CH 70DCH BATTERY CARTRIDGE BP 70EI BATTERY CARTRIDGE BP 70MH ...

Page 5: ...tridge in locations where it will be exposed to a temperature greater than 140ºF 60ºC for an extended period 5 The battery has a limited life When the crimping capacity becomes about 1 2 that of the original capacity the battery should be replaced 6 If the battery cartridge is stored without being charged natural drainage will cause the power to be reduced The battery should be charged every 3 mon...

Page 6: ...ted 3 If the indicator shows a steady red when the battery is inserted the battery is too hot to be charged and must be cooled to room temperature before charging Do not leave the battery in the charger to cool as the charger will not recognize the battery is inserted and will not charge 4 If the LED indicator goes out or is flashing quick red this could be a possible short in the battery circuit ...

Page 7: ...Huskie s technical support department at 1 800 860 6170 5 Continue to advance the blades until the material is cut If material is cut and tool has not yet bypassed it may be difficult to retract blades If this occurs continue to advance tool and build pressure A series of clicks will be heard while the tool running in a neutral mode This indicates that the tool has built full pressure and bypassed...

Page 8: ...6 http www huskietools com info huskietools com MODEL REC 585YC PARTS DIAGRAM ...

Page 9: ...wel Pin G 24 01 1 77 Ram Spring Holder R85 04 1 30 Reservoir Cap 410 55 1 78 Body Head R85 08 1 31 Magnet ROB 25 1 79 M5 X 10 Nylock Screw D 55A 11 1 32 Oil Reservoir 40 551 07 1 80 Grip R85 05 1 33 G 30 O Ring 75 26 1 81 Shoulder Bolt R85 09 1 34 M3 X 16 Screw R150 16 2 82 Thrust Washer 1730 R85 07 1 35 Valve Block R150 17 1 83 Nut AN03 R85 06 2 36 Spring 371 51 17 1 84 Link Head R85 12A 1 37 3 1...

Page 10: ...ry for Repair Service Defective Suction Valve or Bypass Cartridge Consult Factory for Repair Service MOTOR WILL NOT RUN AT ALL Defective Battery Charge or Replace Battery Bad Contact or Loose Battery Connections Check all Connections and Wires Misaligned Switch Check to Make Sure that Switch is Properly Aligned with Trigger Consult Factory for Repair Service TOOL JAWS WILL NOT RELEASE Tool Did Not...

Page 11: ......

Page 12: ...198 N Brandon Drive Glendale Heights Illinois 60139 630 893 7755 Fax 800 345 3767 Toll Free 1 800 860 6170 http www huskietools com info huskietools com 8 06 ...