2.5  Opening the Unit

Caution

 The cover of the product may be removed only by special-

ized staff of the manufacturer or of a service shop properly 
trained and approved by it.

2.6  Extension Cables on the Worksite

To extend power cord length, use exclusively properly approved exten-
sion cables that are labeled as such and have the following conductor 
sections:

up to 20 m:  1.5 mm²  (2.5 mm² recommended);  Type H07RN-F
over 20 m: 

2.5 mm²  (4.0 mm² recommended);  Type H07RN-F

Caution

 

When using the extension cable, it has always to be rolled 
off completely and lie fully extended.

2.7  Checking the Product for Damage

Before every use of the product, check safety features and possibly 
existing parts with minor damage for proper function. Make sure that 
the push-on connection terminals work properly, that contact is fully 
established, and that the contact surfaces are clean. All parts have to 
be installed correctly and properly conform to all conditions in order 
for the product to function as intended. Damaged safety features or 
functional  parts  should  be  properly  repaired  or  replaced  by  an  ap-
proved service shop.

2.8  Power Supply Specifications

2.8.1  Mains Power Supply

Utility suppliers’ wiring requirements, occupational safety rules, ap-
plicable standards, and national codes have to be respected.

Caution

 

When using power distributions on the worksite, rules for the 
installation of earth-leakage circuit breakers (RCD) have to 
be respected, and operation requires an installed breaker.

Generator or mains power fuse protection should be max. 16 A (slow 
blow). The product has to be protected against rain and humidity.

2.8.2  Generator Power Supply

The required nominal generator capacity as determined by the power 
supply  requirement  of  the  largest  fitting  to  be  welded  depends  on 
the power supply specifications, the environment conditions, and the 
generator type itself including its control/regulation characteristics.

Nominal output power of a generator 1-phase, 220 - 240 V, 50/60 Hz:
 

d  20 ....... d 160 

3.2 kW

 

d 160 ...... d 450 

4  kW mechanically regulated

 

 

 

5  kW electronically regulated

Start the generator first, then connect the welding unit. The idle volt-
age should be set to approx. 240 volts. When turning the generator 
off, disconnect the welding unit first.

Important

 The  working  output  power  of  the  generator  decreases  by 

about 10% per 1,000 m of altitude. During the welding pro-
cess no other device connected to the same generator should 
be operated.

Summary of Contents for HST 300 aquatherm 2.0

Page 1: ...ersion Juli 2014 Nieder Ohmener Str 26 35325 M cke Atzenhain 49 0 6401 91 27 0 49 0 6401 91 27 39 info huerner de http www huerner de H RNER SCHWEISSTECHNIK GmbH Biggen 5 57439 Attendorn 49 0 2722 950...

Page 2: ......

Page 3: ...8 5 2 Anschlie en des Fittings 8 5 3 Auswahl der Rohrdimension 8 5 4 Starten des Schwei vorgangs 8 5 5 Schwei prozess 8 5 6 Ende des Schwei vorgangs 9 5 7 Abbruch des Schwei vorgangs 9 5 8 Abk hlzeit...

Page 4: ...Schwei vorgangs 11 8 2 1 Unterspannung 11 8 2 2 berspannung 11 8 2 3 Widerstandsfehler 11 8 2 4 Frequenzfehler 12 8 2 5 Spannungsfehler 12 8 2 6 Strom zu niedrig 12 8 2 7 Strom zu hoch 12 8 2 8 Not Au...

Page 5: ...das Produkt nur unter Beaufsichtigung betreiben vor Inbetriebnahme des Produkts die Bedienungsanleitung genau beachten Vielen Dank 2 Sicherheitshinweise 2 1 Benutzung des richtigen Fitting Adapters V...

Page 6: ...sachgem durch eine Kundendienstwerkstatt repariert oder aus gewechselt werden 2 8 Anschlussbedingungen 2 8 1 Am Netz Die Anschlussbedingungen der Energieversorger Unfallverh tungsvor schriften anwendb...

Page 7: ...rsand Die Anlieferung des Produkts erfolgt in einer Transportkiste Das Produkt ist in dieser Kiste vor Feuchtigkeit und Umwelteinfl ssen gesch tzt auf zubewahren Der Versand des Produkts sollte nur in...

Page 8: ...n des Fittings wird die Rohrdimension d h der Durchmesser des zu verschwei enden Werkst cks mit den Pfeiltasten und ausgew hlt Durch Bet tigen der START SET Taste wird der gew hlte Rohrdurchmesser f r...

Page 9: ...en die Taste gedr ckt wird Es handelt sich um die Softwareversion und die Seriennummer des Ger ts Mit der STOP RESET Taste kann die Anzeige wieder geschlossen werden 6 2 Widerstandsmessung Nach Bet ti...

Page 10: ...ersprache aufgerufen wird vgl Abschn 7 1 1 Datum Uhrzeit M bedeutet dass durch Bet tigen der MEN Taste das Untermen zum Stellen der Uhr aufgerufen wird vgl Abschn 7 1 2 Summer Lautst rke M bedeutet da...

Page 11: ...wendet werden und muss zur Reparatur eingeschickt werden 8 1 6 Temperaturfehler Gemessene Umgebungstemperatur ist au erhalb des Arbeitsbereiches des Ger tes niedriger als 20 C 4 F oder h her als 60 C...

Page 12: ...betr gt der obere Abschaltwert das 1 18 fache des Anfangswertes ansonsten ist die Obergrenze lastabh ngig und liegt 15 ber dem Anlaufstrom 8 2 8 Not Aus Der Schwei vorgang wurde mit der STOP RESET Ta...

Page 13: ...ertrieb aquatherm Biggen 5 Tel 49 0 2722 950 0 57439 Attendorn Deutschland Fax 49 0 2722 950 100 Web www aquatherm de Mail info aquatherm de Hersteller H RNER Schwei technik GmbH Nieder Ohmener Str 26...

Page 14: ......

Page 15: ...5 2 Connecting the Fitting 8 5 3 Selecting the Pipe Dimension 8 5 4 Starting the Welding Process 8 5 5 Welding Process 8 5 6 End of Welding 8 5 7 Aborted Welding Process 9 5 8 Cooling Time 9 5 9 Retu...

Page 16: ...g Welding 11 8 2 1 Low Voltage 11 8 2 2 Overvoltage 11 8 2 3 Resistance Error 11 8 2 4 Frequency Error 12 8 2 5 Voltage Error 12 8 2 6 Low Current 12 8 2 7 Excess Current 12 8 2 8 Emergency Off 12 8 2...

Page 17: ...tion maintenance and service of the product have to be properly qualified operate the product only when observed read carefully and conform to the User s Manual before working with the product Thank y...

Page 18: ...repaired or replaced by an ap proved service shop 2 8 Power Supply Specifications 2 8 1 Mains Power Supply Utility suppliers wiring requirements occupational safety rules ap plicable standards and nat...

Page 19: ...s box protects the product from humidity and environmental agents When sending the product it should be placed into the transport box at all times 4 Principles of Operation The HST 300 aquatherm 2 0 a...

Page 20: ...hen the fitting is connected the pipe dimension i e the diameter of the parts that are going to be welded is selected using the arrow keys and By pressing the START SET key the selected dimension is a...

Page 21: ...P RESET key 6 2 Measuring Resistance When the START SET key was pressed to initiate a welding process the resistance value of the fitting is measured and compared to the value that matches the entered...

Page 22: ...can access a sub menu for setting the clock see Sect 7 1 2 Buzzer Volume M means that by pressing the MENU key the user can access a sub menu for setting the volume of the status buzzer see Sect 7 1 3...

Page 23: ...o be sent to an approved shop for check and repair 8 1 6 Temperature Error The ambient temperature measured is outside the operating range of the welding unit i e below 20 C 4 F or over 60 C 140 F 8 1...

Page 24: ...s the value at start in any other case the upper limit depends on the load value and is calculated as the current at start plus 15 8 2 8 Emergency Off The welding process has been interrupted by press...

Page 25: ...erm Biggen 5 Tel 49 0 2722 950 0 57439 Attendorn Germany Fax 49 0 2722 950 100 Web www aquatherm de Mail info aquatherm de Manufacturer H RNER Schweisstechnik Nieder Ohmener Str 26 Tel 49 0 6401 9127...

Page 26: ......

Page 27: ...udage 8 5 2 Raccordement du manchon au poste de soudage 8 5 3 S lection de la dimension du tube 8 5 4 D but du soudage 8 5 5 Proc dure de soudage 8 5 6 Fin du soudage 9 5 7 Interruption du soudage 9 5...

Page 28: ...oudage 11 8 2 1 Tension insuffisante 11 8 2 2 Surtension 11 8 2 3 Erreur r sistance 11 8 2 4 Erreur fr quence 12 8 2 5 Erreur tension 12 8 2 6 Courant bas 12 8 2 7 Courant excessif 12 8 2 8 Arr t d ur...

Page 29: ...d ment habilit es travailler avec le produit seulement quand il est surveill respecter les consignes donn es dans le manuel utilisateur du poste de soudage Merci beaucoup 2 Consignes de s curit 2 1 C...

Page 30: ...ls de l appareil faire appel de pr f rence un atelier agr pour faire r parer ou remplacer les pi ces en question 2 8 Alimentation 2 8 1 Alimentation secteur Les exigences de c blage des distributeurs...

Page 31: ...e faire r viser le produit au moins une fois par an 3 2 Transport Conservation Livraison Le produit vous est livr dans une bo te de transport Le produit devrait tre conserv dans cette bo te prot g des...

Page 32: ...sont encrass s ou d grad s Apr s que le contact a t tabli entre le poste de soudage et le raccord traiter le texte Pas de contact dispara t cf l cran 2 5 3 S lection de la dimension du tube La s lecti...

Page 33: ...cran Contacter raccord la touche est enfonc e Il s agit de la version du logiciel et du num ro de s rie du poste Cet cran se referme suite une action sur la touche STOP RESET 6 2 V rification de la r...

Page 34: ...ui permet de choisir la langue des textes affich s et figurant dans les rapports voir la section 7 1 1 Date Heure M l action sur la touche MENU ouvre un sous menu qui permet de r gler l horloge intern...

Page 35: ...xp di un atelier agr pour r paration 8 1 6 Erreur temp rature ambiante La temp rature ambiante relev e par l appareil n est pas conforme aux conditions requises c est dire inf rieure 20 C 4 F ou sup r...

Page 36: ...s la valeur du courant au d marrage sinon la valeur maximale d pend de la charge et est sup rieure de 15 au courant au d marrage 8 2 8 Arr t d urgence Le soudage a t interrompu par une action sur la t...

Page 37: ...therm Biggen 5 Tel 49 0 2722 950 0 57439 Attendorn Allemagne Fax 49 0 2722 950 100 Web www aquatherm de Mail info aquatherm de Fabricant H RNER Schweisstechnik Nieder Ohmener Str 26 Tel 49 0 6401 9127...

Page 38: ...ette d claration sont conformes aux normes et documents de normalisation suivants CE Konformit t CE Conformity Conformit CE Richtlinie 2004 108 EG Richtlinie 2006 95 EG Andere Normen Other Standards A...

Reviews: