Version August 2017
14
EN
HÜRNER HCU 300 User’s Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
6.5
Entering the Installing Company
In the same manner as the fitting traceability code (see
Sect. 6.4), entering a maximum of 15 characters for the
company that performs the installation or reading its name
from a bar code is possible, if this feature was enabled in
the configuration (see Sect. 10.2).
7
Entering Welding Parameters Manually
To be able to enter the welding parameters manually, you
have first to connect the fitting to the welding unit with
the welding cable. Manual parameter input can then be
accessed by pressing the
ò
arrow key. The screen will show
a menu as reproduced in Display 10, provided manual input
is enabled in the configuration menu (see Sect. 10.1).
Using the arrow keys
ñ
and
ò
you can select “Enter Volt-
age/Time” or “Enter Fitting Code” (i.e., the ordered string
of numbers that represents the fitting code). Confirm your
selection by pressing the START/SET key.
7.1
Manually Entering Welding Voltage and Time
If this option was chosen in the manual parameter input
menu, a display like the one to the right appears on the
screen. Use the alphanumeric keypad (see Info in Sect. 5.2)
to set the welding voltage and the welding time, accord-
ing to the fitting manufacturer’s instructions, then press
the START/SET key to confirm your input. The “Start ?”
message displayed after the confirmation by START/SET
indicates that the unit is ready for welding.
7.2
Entering the String of Numbers
If this option was chosen in the manual parameter input
menu, the “Enter Fitting Code” display shows. The 24 char-
acters of the fitting code to be entered display as asterisks
(
*
). Use the alphanumeric keypad (see Info in Sect. 5.2)
to enter the code and press START/SET to confirm your
input and have it decoded. If the code entered is not cor-
rect, an “Input Error” message appears; check the string
of numbers and correct as needed. If the code is correct,
the decoded data is displayed, and the “Start ?” message
indicates that the unit is ready to start welding.
8
Downloading the Reports
Interface
(see next page)
Display 10
** Manual Input **
Enter Voltage/Time
>Enter Fitting Code
Display 11
Voltage/Time
U= 40 V t= 1000 s