033-9900 User Manual Q6 (Advanced 6 year old) Rev. M
©2016 Humanetics Innovative Solutions Inc.
©
Page 44 of 96
4.6 Pelvis
Construction
The pelvis casting is a single metal casting which fits into the pelvis flesh. The two
items are completely separable. The upper legs, with the ball and socket hip joint
assemblies, fit into the two openings at the left and right side of the pelvis.
Table 12.
Pelvis assembly parts
Description
Part No.
Qty. in Assembly
Pelvis assembly
033-7000
1
Pelvis casting machined
033-7001
1
Pelvis Flesh
033-7002
1
Hip joint Lower
020-7201
2
Hip joint Upper
020-7202
2
Hip joint Spacer
020-7203
2
Screw SHCS M5 x 12
5000002
4
Screw BHCS M4 x 12
5000005
4
Assembly and Disassembly
Disassembly
1.
If necessary, remove the dummy’s upper part by removing the M6 x 43 bolts
(020-9902) at the lumbar spine thorax interface.
2.
Remove the lumbar spine and load cell (or load cell structural replacement) as
described in section 4.5.
Legs
3.
Remove the left and right legs. To do so, put the dummy on its back or front,
and remove the four M5 x 12 screws in the crotch area that retain the hip joint
assemblies.
4.
With the screws removed from the dummy, the legs together with the hip joint
assemblies can be removed from the pelvis by pulling them laterally outwards.
5.
Hip joint assemblies can be removed from the legs through separation of the
upper and lower hip joint. Do so by removal of the four button head M4
screws (see