033-9900 User Manual Q6 (Advanced 6 year old) Rev. M
©2016 Humanetics Innovative Solutions Inc.
©
Page 45 of 96
Note: It is possible to change the friction setting of the hip joints. To do so the
spacer between the hip cups must be removed. This is only done when doing
out of position testing to lock the leg at the hip.
Skin
6.
When the legs are removed, the pelvis flesh can be removed from the pelvis
casting by pulling it downward.
Assembly
Perform steps 1 to 6 under “Disassembly” in reverse order.
Figure 18.
Pelvis and hip joint assembly
Instrumentation
Accelerometers
The pelvis can be equipped with a mounting block accepting three uni-axial
accelerometers or a single tri-axial accelerometer. In order to use accelerometers
in the pelvis, first mount them onto the mounting block. The tri-axial