
Chapter 2 • Pointing the antenna
1037663-0001 Revision A
15
Upon entering the Point state, the DAPT display reads:
where
S
or
L
indicates either the “short” or “long” time
constant filter respectively, and
SQF
is a value from 0 - 255.
The left SQF value in row 2 is the highest recorded value
during the current phase; the value at right is the current
value. For example, the actual display may appear as follows:
In this example, the short filter is in use (indicated by the
S
in
the top row). The highest recorded SQF value is 171 points,
and the current SQF reading is 94 points.
2. Choose either the long or the short filter by pressing
Toggle
(button 2). Each press of this button toggles the selection.
3. Wait for the SQF reading to settle on a value, then use the
appropriately sized wrench for the antenna you are pointing
to adjust the antenna azimuth and elevation as shown in
Figure 8, until you achieve the highest possible SQF value.
Summary of Contents for HughesNet Ka-band
Page 1: ...1037663 0001 Revision A March 26 2008 Ka Band Antenna Pointing Guide ...
Page 4: ... Contents iv 1037663 0001 Revision A ...
Page 6: ... Figures vi 1037663 0001 Revision A ...
Page 8: ... Tables viii 1037663 0001 Revision A ...
Page 14: ...Chapter 1 Introduction 6 1037663 0001 Revision A ...
Page 40: ...Chapter 2 Pointing the antenna 32 1037663 0001 Revision A ...
Page 42: ... Acronyms and abbreviations 34 1037663 0001 Revision A ...