Chapter 8 • Configuring the HN router for VADB backup
1037753-0001 Revision A
63
Installing the protection
module
To install a protection module, refer to Figures 54 through 56 and
follow these instructions:
1. Connect the short telephone cable from the protection module
MODEM port to the HN router TEL LINE port, as shown in
Figure 55.
2. Remove the coaxial cable from the HN router SAT IN port.
See Figure 56.
3. Slip the ring terminal at the end of the protection module
grounding cable over the SAT IN terminal post.
Figure 55: Connecting the protection module to the terminal
Short
phone
cable
Ground
cable
Protection
module
Longer
phone
cable
MODEM
port
LINE
port
HN7700S
TEL LINE
port
T0155016
HN7700S
backplane
CAUTION
Do not remove or loosen the factory-installed hex nut on the
HN router SAT IN port. Use the hex nut supplied with the
protection module kit to secure the ring terminal attached to
the protection module ground cable.
Figure 56: Connecting the protection module ground cable
Ground
cable from
protection
module
T0155015
HN7700S backplane
Do not remove or
loosen the
hex nut.
factory-
installed
Use hex nut supplied with
the protection module to
secure the ring terminal.
Summary of Contents for HN7700S
Page 4: ... Important safety information iv 1037753 0001 Revision A ...
Page 14: ... Tables xiv 1037753 0001 Revision A ...
Page 28: ...Chapter 3 Assembling and connecting the HN router hardware 14 1037753 0001 Revision A ...
Page 50: ...Chapter 5 Commissioning the HN router 36 1037753 0001 Revision A ...
Page 62: ...Chapter 7 System Control Center 48 1037753 0001 Revision A Figure 41 LAN Info page ...
Page 82: ...Chapter 8 Configuring the HN router for VADB backup 68 1037753 0001 Revision A ...
Page 106: ...Appendix C Disabling a Web browser s proxy connection 92 1037753 0001 Revision A ...
Page 130: ...Appendix E ADTRAN Total Access 600R 116 1037753 0001 Revision A ...
Page 138: ... Acronyms and abbreviations 124 1037753 0001 Revision A ...