![Hughes Network Systems DiRECWAY DW4000 Installation Manual Download Page 25](http://html1.mh-extra.com/html/hughes-network-systems/direcway-dw4000/direcway-dw4000_installation-manual_2182222025.webp)
21
INSTALLING THE AZ/EL CAP ONTO THE SATELLITE DISH
You will set the satellite dish's elevation and polarization,
which you wrote down in this manual on page 4, before attach-
ing the azimuth/elevation (AZ/EL) cap to the satellite dish. As
you set them, refer to Figure 26. Note the cap has an arrow,
labeled “Top,” to show you how to orient the cap vertically (see
Figure 29 on page 22).
1. Use a 1/2-inch socket wrench or open-end wrench to loosen
the four polarization nuts.
2. Refer to page 4 of this manual to find the elevation value.
3. Orient the AZ/EL cap so that the “TOP” label is at the upper
right. The elevation bolt will also be on the right.
4. Use a 1/2-inch socket wrench or open-end wrench to loosen
the AZ/EL bracket bolt nut and elevation nuts.
5. Using your fingers, retighten the three nuts until you cannot
tighten them further.
6. Still using your fingers, loosen each of the nuts one revolu-
tion.
7. Locate the red elevation reference mark on the elevation
scale on the left side of the cap assembly. See Figure 27 and
Figure 28 on the next page to help you locate the mark. The
leading edge of the metal plate is the elevation reference
mark.
8. Use a 1/2-inch socket wrench or open-end wrench to turn
the elevation bolt head until the leading edge of the mark is
at the correct value. You may need to turn the bolt head a
number of times until the leading edge of the red mark
reaches the correct value.
9. When the leading edge of the red mark is at the correct ele-
vation value, tighten the bracket bolt nut and the two eleva-
tion nuts. Do not tighten the elevation pivot nut.
10. Refer to page 4 to find the polarization value.
11. Locate the polarization scale. It is at the top of the AZ/EL
cap (see Figure 29).
12. Turn the AZ/EL to the correct polarization value. Align the
mark on the top of the AZ/EL with the correct value on the
polarization scale. Figure 29 shows a setting of positive 3
degrees. Each tick mark represents 2 degrees.
PARTS NEEDED
TOOLS NEEDED
• Azimuth/Elevation (AZ/EL) cap
• Satellite dish
• 5/16-inch Nylock nuts, Qty: 4
• 5/16-inch flat
washers, Qty: 4
• 7/16-inch open-end wrench or socket wrench
• 1/2-inch open-end wrench or socket wrench
• Torque wrench (with 1/2-inch socket capable of
torquing to 12 ft.-lbs.)
Figure 26
Bracket bolt nut
Elevation bolt head
Elevation bolt
Clamp bolts (3)
Elevation pivot
Polarization nuts (4)
TOP label
Polarization scale
Elevation nuts (one on each side)
Summary of Contents for DiRECWAY DW4000
Page 4: ...iv ...