Winding the rope on the drum
To do this, tauten the rope and wind it with joined strands onto the drum.
Reminder
: the maximum capacity of these winches is 15 m of rope with a diameter of 4 mm, 16 m of
rope with a 5 mm diameter or 13.5 m of rope with a 6 mm diameter depending on the models.
Very important
: The safety regulations require that 3 loops of rope always be left on the drum. If the
rope and the hook used were not supplied by the manufacturer with the machine, check that they
guarantee a level of safety corresponding to coefficient 5.
The first layer must be wound in a compact manner and under tension. Take a mallet or a block of
wood and knock the turns against one another; not too hard to prevent the strands from overlapping
one another, but tightly enough to prevent the rope from moving on the drum. If the first layer is
wound too loose, the next layer will form a space in the first layer that will result in an open area. If
the first layer is too tight, the subsequent layers will not have enough space between turns.
In any case, the first layer and all the other layers must be wound onto the drum with enough pre-
tension (5-10 % of the MWL of the rope). If the rope is wound without any tension, it will suffer from
crushing and premature flattening caused by the loaded upper layers.
Even if the first layer is wound correctly during installation, it will expand a little while in service.
When the first layer expands (loss of pre-tension) the initial procedure MUST be performed at regular
intervals.
Otherwise, the "hard" turns will severely crush the base layers.
Whatever you do, DO NOT pass the rope through a clamping mechanism. For example, two blocks of
wood screwed together.
THIS WILL CAUSE IRREPARABLE DAMAGE TO THE ROPE
!
It is important
to respect the indication below; if the rope start on the winch is at the bottom,
respect the same principle. Not respecting this precaution will damage your rope irretrievably and it
will become extremely dangerous.
Check the direction of cable winding according to the motor connection.