UO-SPN-1
Operating and configuration manual
UO-SPN1_Manual-en_R4
11
4
Technical data and functions
4.1
Type plate
The following image shows an example of a type plate.
The type plate is located on the outside of
the housing, and includes the following
information:
Manufacturer
Type, year of construction
CE mark
Serial number (S/N)
Protective class
Power consumption
ID number
Liquidation
MAC address
Certification information
4.2
Type designation
UO-SPN -1
SPN function module
1:
Variation 1
4.3
Electrical data
Information
Value
Supply voltage
Delivered to the SCU module via the bus connector
Additional UO-SPN-1 module
power consumption
< 4 W
Overall resolution
28 Bit
Protective class in accordance
with DIN EN 60529
IP20 for cabinet installation
Degree of protection of cabinet:
≥ IP54
Singleturn functional
13 Bit (8192 steps/revolution)
Singleturn safety-specific
8 Bit (256 steps/revolution)
Multiturn
15 Bit (32768 revolutions)
PROFINET IO interface
in accordance with IEC 61158 and IEC 61784
PROFIsafe profile
3.192b in accordance with IEC 61784-3-3
Fig. 4-1: Type plate (example)