Incremental Hollow Shaft Encoder FGHJ 5
18
FGHJ5_MANUAL-en_R4(2018-11-05)ID74524.docx
8
Inspections
8.1
Safety instructions
Personnel
Dismantling must be carried out by skilled technical staff only.
Attention: Observe safety instructions 2 before starting any tasks.
(Installation/maintenance/disassembly).
8.2
Maintenance information
The device is maintenance free. However the following tests are recommended to ensure optimal,
problem free operation.
8.3
Inspection schedule
Interval
Tests
Tasks
Every 12 month
Check coupling
Qualified person
Every 12 month
Check the fastening screws for
firm seat
Qualified person
Every 12 month
Check the cable connections
Qualified person
After approx. 16000 to 20000
operating hours and high long-
term loading
Check deep-groove ball
bearing for ease of movement
and noise.
Qualified person
Worn ball bearings have to be
replaced only by the
Manufacturer
Hubner
– Giessen Service
9
Disposal
The manufacturer is not obligated to take back electronics waste. The device consists of hybrid
components, and in part must be disposed of as special waste (electronic scrap) according to country-
specific legislation.
Local municipal authorities or specialized disposal companies provide information on environmentally
responsible disposal.