background image

 

 

TECHNICAL BULLETIN 

 

V1.2.0en/05.02.16 

Liability for errors and misprints excluded. 

Profibus® Gateway SE 

Table of Contents 

V1.2.0en/05.02.16 

1

 

Description .................................................................................. 6

 

2

 

Information on the functioning of the Profibus Gateway SE ........ 6

 

2.1

 

Position of the Profibus Gateway SE within the data transmission .................. 6

 

3

 

Installation instructions ............................................................... 7

 

3.1

 

Installation provided by the customer ............................................................ 7

 

4

 

Commissioning of the Profibus Gateway SE ................................. 7

 

5

 

Integration into the process automation system ........................... 8

 

5.1

 

Basic mode of operation of the Profibus Gateway SE ...................................... 8

 

5.2

 

Description of the standard variant ................................................................ 8

 

6

 

Properties of standard variables .................................................. 9

 

6.1

 

“vSP” – Setpoint, temperature controller ....................................................... 9

 

6.2

 

“vTI” – Internal temperature .......................................................................... 9

 

6.3

 

“vpP” – Pump pressure (absolute) .................................................................. 9

 

6.4

 

“vError” – Error report ................................................................................... 9

 

6.5

 

“vWarn” – Warning message .......................................................................... 9

 

6.6

 

“vTE” – Process temperature (Lemosa) ........................................................... 9

 

6.7

 

“vStatus1” – Status of the thermostat .......................................................... 10

 

6.8

 

“vTmpMode” – Temperature control mode .................................................. 10

 

6.9

 

“vTmpActive” – Temperature control ........................................................... 10

 

6.10

 

“vSNRL + vSNRH” – Serial number ................................................................ 10

 

7

 

Diagnostic functions .................................................................. 11

 

7.1

 

On commissioning ........................................................................................ 11

 

7.2

 

During operation .......................................................................................... 11

 

7.3

 

Troubleshooting ........................................................................................... 11

 

 

 

 

Summary of Contents for Profibus SE

Page 1: ...Technical Bulletin Profibus Gateway SE V1 2 0...

Page 2: ...TECHNICAL BULLETIN Profibus Gateway SE Liability for errors and misprints excluded V1 2 0en 05 02 16 2...

Page 3: ...TECHNICAL BULLETIN V1 2 0en 05 02 16 Liability for errors and misprints excluded Profibus Gateway SE 3 Profibus Gateway SE...

Page 4: ...TECHNICAL BULLETIN Profibus Gateway SE Liability for errors and misprints excluded V1 2 0en 05 02 16 4...

Page 5: ...into the process automation system 8 5 1 Basic mode of operation of the Profibus Gateway SE 8 5 2 Description of the standard variant 8 6 Properties of standard variables 9 6 1 vSP Setpoint temperatur...

Page 6: ...standard version presented is designed to cover a large number of process requirements We can offer a customized version if you have addi tional requirements Please note the inherent restrictions of E...

Page 7: ...topology in accordance with the requirements of the PROFIBUS user organization A bus termination can be enabled on the Pro fibus Gateway SE The Profibus Gateway SE has been built and qualified in acc...

Page 8: ...fore always available when retrieving the process image The temperature control unit can immediately return the current process values when a Profibus frame is received On the other hand the update lo...

Page 9: ...lute Absolute pump pressure at the pressure sensor in the thermal fluid circuit of the thermostat only if there is a pressure sensor 6 4 vError Error report The number of the error report that appeare...

Page 10: ...e activated not activated 14 Restart electronics Power failure no restart restart 15 Freeze protection not available on all devices active inactive This bit is reset to 0 when the control is restarted...

Page 11: ...illuminated when a command is sent from the Profibus Gateway SE via the serial interface and turns off after a response has been received The Profibus plug must not be plugged in when in this mode To...

Page 12: ...Diagnostic functions TECHNICAL BULLETIN Chapter 7 Profibus Gateway SE Liability for errors and misprints excluded V1 2 0en 05 02 16 12...

Page 13: ......

Page 14: ...Peter Huber K ltemaschinenbau AG Werner von Siemens Stra e 1 D 77656 Offenburg Germany tel 49 781 9603 0 fax 49 781 57211 e mail info huber online com www huber online com Hotline 49 781 9603 244...

Reviews: