INSTALLATION MANUAL
MASTERLINE Ultimate Power
Page 10 of 11
HUBER+SUHNER disclaims any liability resulting from incorrect installation and use, including any damages resulting from the use of tools and
accessories other than the ones recommended herein. Any installation performed by unqualified personnel voids the product warranty provided by
HUBER+SUHNER. All due care and attention must be exercised when performing the installation of these products. For advice concerning the
general handling of these products please contact HUBER+SUHNER.
POWER CODING
Power connector
number on MLUP
connector head
RRH end
Power jumper 2-core cable
BTS end
Multi-core power cable
conductor color code
conductor numbering / color code
Option 1
(Europe)
Option 2
(USA)
Option 3
(USA)
Option 1
(Europe)
Option 2
(USA)
1L
Brown
Black
Black
1-White
1-Black
Blue
Grey
White
2-White
2-White
Braided screen
Braided screen
2L
Brown
Black
Black
3-White
3-Red
Blue
Grey
White
4-White
4-Green
Braided screen
Braided screen
3L
Brown
Black
Black
5-White
5-Orange
Blue
Grey
White
6-White
6-Blue
Braided screen
Braided screen
1R
Brown
Black
Black
7-White
7-White/Black
Blue
Grey
White
8-White
8-Red/Black
Braided screen
Braided screen
2R
Brown
Black
Black
9-White
9-Green/Black
Blue
Grey
White
10-White
10-Orange/Black
Braided screen
Braided screen
3R
Brown
Black
Black
11-White
11-Blue/Black
Blue
Grey
White
12-White
12-Black/White
Braided screen
Braided screen